Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush
نویسندگان
چکیده
OBJECTIVE To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. DESIGN Case series. SUBJECTS AND PARTICIPANTS Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. MAIN OUTCOME MEASURES Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. RESULTS Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). CONCLUSION Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.
منابع مشابه
Gold shunt for refractory advanced low-tension glaucoma with spared central acuity
The aim of this study is to report a case of gold shunt surgery for uncontrolled, low-tension glaucoma with good central vision, after having a previously failed trabeculectomy and tube shunt surgeries. The patient was receiving maximum medical glaucoma therapy of four different types with intraocular pressure of 17 mm Hg prior to gold shunt surgery. Five years later, intraocular pressure is we...
متن کاملSurgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma
AIM To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. MATERIALS AND METHODS A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met ...
متن کاملIncidence of postoperative suprachoroidal hemorrhage after glaucoma filtration surgeries in the United States
PURPOSE To report the 3-month incidence rates of postoperative suprachoroidal hemorrhage after glaucoma filtration surgeries and to examine the subsequent surgical treatments in these eyes. METHODS This is a retrospective study using the nationally pooled, insurance claim-based MarketScan databases from the years 2007-2011. Patients with records of trabeculectomy and/or tube shunt procedures ...
متن کاملResults of Trabectome Surgery Following Failed Glaucoma Tube Shunt Implantation
To evaluate the safety and efficacy of Trabectome after failed tube shunt surgery.Twenty patients with prior failed tube shunt surgery who underwent Trabectome alone were included. All patients had at least 3 months of follow-up. Outcomes measured included intraocular pressure (IOP), glaucoma medications, and secondary glaucoma surgeries. The success for Kaplan-Meier survival analysis is define...
متن کاملUpdate on Tube-Shunt Procedures for Glaucoma
Present-day glaucoma implants, i.e., long-tube implants, were introduced by Molteno et al. in 1976 [31]. !e most commonly used implants include Molteno and Ahmed singleand doubleplate implants, and the Baerveldt and Krupin implants. All implants are long-tube implants based on the original Molteno design. !e Ahmed and Krupin implants are valved implants. !e most recent addition to tube-shunt de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2015