Phenotypic differences in cardiovascular regulation in inbred rat models of aerobic capacity.

نویسندگان

  • L G Koch
  • S L Britton
  • J C Barbato
  • D W Rodenbaugh
  • S E DiCarlo
چکیده

The Dark Aouti (DA) inbred strain of rats has superior aerobic treadmill running capacity compared with the Copenhagen (COP) strain of inbred rats. This difference in aerobic capacity provides a model to explore the genetic basis of variation in this trait. The present study evaluated intermediate phenotypic differences between 10 male COP inbred rats and 10 male DA inbred rats that might contribute to the difference in aerobic capacity between the strains. Five autonomically regulated cardiovascular variables were evaluated during rest or exercise by measuring the response to autonomic antagonists. The DA rat had enhanced autonomic function for the regulation of peripheral blood flow and cardiac output. Specifically, at rest the DA rats had significantly more sympathetic (123 +/- 8 vs. 99 +/- 7 beats/min) and parasympathetic (35 +/- 5 vs. 12 +/- 3 beats/min) tonus for heart rate control and more sympathetic support of blood pressure (70 +/- 7 vs. 38 +/- 6 mmHg) compared with the COP rats. During three graded levels of treadmill exercise the DA rats had higher blood pressures (16% on average) and higher heart rates (4% on average) relative to the COP rats. In addition, the DA rats had a 27% greater heart weight-to-body weight ratio compared with the COP strain of rats (3.63 +/- 0.08 vs. 2.85 +/- 0.07 g/kg). All five of these intermediate phenotypes could participate as variables causative of the difference in treadmill running capacity between the DA and COP strains of rats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrum of aerobic endurance running performance in eleven inbred strains of rats.

The goal of this study was to identify inbred rat strains that could serve as useful models for exploration of the genetic basis of aerobic endurance performance. Six rats of each gender from 11 different inbred strains were tested for 1) maximal running capacity on a treadmill and 2) isolated cardiac performance. Running performance was estimated from 1) duration of the run, 2) distance run, a...

متن کامل

Cardiac adenosine production in rat genetic models of low and high exercise capacity.

We previously demonstrated that Copenhagen (COP) and DA inbred rat strains show a wide difference in a test for aerobic treadmill running that correlated positively with isolated cardiac function. The purpose of this study was to test adenosine production as a candidate intermediate phenotype that may explain part of the difference in running and cardiac performance in these genetic models for ...

متن کامل

A genome scan for Loci associated with aerobic running capacity in rats.

Aerobic capacity is a complex trait that defines the efficiency to use atmospheric oxygen as an electron acceptor in energy transfer. Copenhagen (COP) and DA inbred rat strains show a wide difference in a test for aerobic treadmill running and serve as contrasting genetic models for aerobic capacity. A genome scan was carried out on an F(2)(COP x DA) segregating population (n=224) to detect qua...

متن کامل

Evaluation of nicotinic receptor of pedunculopontine tegmental nucleus in central cardiovascular regulation in anesthetized rat

Objective(s): Cholinergic neurons are important neurons in the Pedunculopontine tegmental nucleus (PPT). In this study, nicotinic receptor of the PPT in central cardiovascular regulation in the anesthetized rat was evaluated. Materials and Methods: Saline, acetylcholine (Ach; doses: 90 and 150 nmol), hexamethonium (Hexa; doses: 100 and 300 nmol) and higher doses of Hexa (300 nmol) + Ach (150 nm...

متن کامل

Myocardial function in rat genetic models of low and high aerobic running capacity.

We recently evaluated treadmill aerobic running capacity in 11 inbred strains of rats and found that isolated working left ventricular function correlated (r = 0.86) with aerobic running capacity. Among these 11 strains the Buffalo (BUF) hearts produced the lowest and the DA hearts the highest isolated cardiac output. The goal of this study was to investigate the components of cardiac function ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological genomics

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 1999