Evaluation of the BD ProbeTec CTQ Amplified DNA Assay for Detection of the New Chlamydia trachomatis Variant in Sweden
نویسندگان
چکیده
OBJECTIVES The nvCT has a 377 bp plasmid deletion that has caused commonly used nucleic acid amplification tests to generate false negative results. In Swedish counties nvCT has been reported to account for up to 65% of all chlamydia cases in 2007. The aim was to evaluate the CTQ DNA amplification assay for detection of the new Chlamydia trachomatis variant (nvCT) in urine specimens from a laboratory in Sweden. METHODS In this study, 199 unscreened urine specimens were collected and tested using the BD ProbeTec ™ ET CT assay and then tested with the BD ProbeTec ™ CTQ assay on the BD Viper System in extracted mode. Discrepant cases were tested with real time PCR. 1 The CTQ assay targets a region of the Cryptic Plasmid outside the 377 bp deletion found in nvCT strains. An additional 30 urine specimens collected in March 2008 and identified as positive with nvCT PCR 2 were also tested on the CTQ assay for verification of detection accuracy. RESULTS Of the 199 unscreened urine samples, 34 (17%) were positive in the routine BD ProbeTec ™ ET CT compared to 36 (18%) tested positive in the CTQ assay (Table 1). Three cases were positive only with BD ProbeTec CTQ assay and two of these were positive also with real time PCR. One case was only positive by BD ProbeTec ET CT assay and was also negative in the real time PCR. In the collection of 30 urine specimens with nvCT all were detected by the CTQ assay. Pos Neg BD ProbeTec CTQ Pos 33 3 Neg 1 162 CONCLUSION The BD ProbeTec CTQ assay can adequately detect nvCT and wild type strains of C. trachomatis.
منابع مشابه
Clinical Evaluation of the BD ProbeTecTM Chlamydia trachomatis Q Amplified DNA Assay on the BD ViperTM System With XTRTM Technology
Background: This study evaluated the performance of the BD ProbeTec Chlamydia trachomatis Q (CTQ) Amplified DNA Assay on the BD Viper System with XTR Technology in a multicenter study. Methods: Specimens were collected at 7 geographically diverse clinical sites from 1538 women and men attending sexually transmitted disease, family planning, and obstetrics and gynecology clinics. There were 1465...
متن کاملA two-site analytical evaluation of the BD Viper System with XTR Technology in Nonextracted Mode and Extracted Mode with seeded simulated specimens.
The BD ProbeTec CT Q(x) Amplified DNA Assay and the BD ProbeTec GC Q(x) Amplified DNA Assay (both BD Diagnostics, Sparks, MD) represent two new assays developed for use with the BD Viper System with XTR Technology (BD Diagnostics). These assays were built on the foundation of the former BD ProbeTec ET assays (BD Diagnostics) and its accompanying instrumentation. The study described below compar...
متن کاملComparison of the BD Viper System with XTR Technology to the Gen-Probe APTIMA COMBO 2 Assay using the TIGRIS DTS system for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine specimens.
BACKGROUND Performances of the BD ProbeTec Chlamydia trachomatis (CT)/Neisseria Gonorrhoeae (GC) Q(x) Amplified DNA Assay reagents on a BD Viper System with XTR Technology and APTIMA COMBO 2 Assay reagents on a TIGRIS DTS platform, for detection of both CT and GC were compared. METHODS A total of 1018 first-void urine specimens were tested for the presence of CT and GC DNA using the 2 assays....
متن کاملEvaluation of the New BD Max GC Real-Time PCR Assay, Analytically and Clinically as a Supplementary Test for the BD ProbeTec GC Qx Amplified DNA Assay, for Molecular Detection of Neisseria gonorrhoeae.
The new BD Max GC real-time PCR assay showed high clinical and analytical sensitivity and specificity. It can be an effective and accurate supplementary test for the BD ProbeTec GC Qx amplified DNA assay, which had suboptimal specificity, and might also be used for initial detection of Neisseria gonorrhoeae.
متن کاملDirect comparison of the BD ProbeTec ET system with in-house LightCycler PCR assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae from clinical specimens.
The commercial BD ProbeTec ET (BDPT) system for the detection of Neisseria gonorrhoeae and Chlamydia trachomatis from clinical specimens was compared with our in-house LightCycler real-time PCR (LC-PCR) assays. Specimens initially positive by the BDPT system were retested by our LC-PCR assays. Our results for C. trachomatis testing indicate a 91.2% agreement when the results of 114 clinical spe...