چکیده
A new intelligent isolation system combining a piezoelectric damper with laminated rubber bearing is proposed. and used in a practical example in this paper, LQR and GPC chose as the control algorithm according to the damper. The characteristic of these two kinds of algorithm is analyzed and is used in the civil engineering vibration controlling. The results of the analysis show the performance of above new isolation device is excellent. The seismic response of the super-structure is significantly reduced. The drift displacement and floor acceleration of the structure is significantly reduced at the same time; in addition this system is also effective whenever in frequently occurred earthquake or seldomly occurred earthquake for the damping force can be changed of the frictional damper.
منابع مشابه
Response Modification Factor of Chevron Braced Frame With Pall Friction Damper
Response modification factors (R-factor) are used in current seismic building codes to reduce earthquake forces associated with seismic design level to determine force levels. In recent years, many authors have shown great interest in the development of seismic structural systems and several theoretical and experimental studies have been conducted to investigate performance of dampers but littl...
متن کاملPerformance Evaluation of Viscoelastic and Friction Passive Damping System in Steel Structures
Additional dampers are employed in order to decrease the dynamic response of structure against the earthquake and wind loading recently. In this study, two types of systems related to waste of inactive energy, i.e. frictional damper which is categorized in dampers dependent on movement and viscoelastic damper which is categorized in dampers dependent on velocity, in making steel structures resi...
متن کاملExploring the Efficiency of Dampers for Repair and Strengthening of Existing Buildings
In this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. Seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. The finite element modeling technique (SAP2000 Software) is used for analysis. Time History analyzing was done to achieve this purpose. For nonlinear dynamic analysis, the responses of ...
متن کاملFuzzy control of piezoelectric friction dampers for seismic protection of smart base isolated buildings
This study proposes two fuzzy logic controllers (FLCs) for operating control force of piezoelectric friction dampers used for seismic protection of base-isolated buildings against various types of earthquake excitations. The first controller employs a hierarchic control strategy in which a higher-level supervisory controller operates a single sub-level FLC by modifying its input normalization f...
متن کاملThe 14th World Conference on Earthquake Engineering
Semi-active control devices have been shown to be more energy efficient than active devices and more effective in reducing seismic structural vibration than passive devices. A new type of semi-active control device, the piezoelectric friction damper has been made in this paper. Piezoelectric actuators used in the dampers can quickly and accurately respond to a voltage signal. They are also effe...
متن کامل