Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor

نویسندگان

  • Suw Young Ly
  • Hai-Soo Yoo
  • Minki Jung
  • Kwang Hee Ko
  • Byung Jin Kim
  • Ki Chul Lee
  • Byung Min Choi
چکیده

The analytical in vivo chromium ion was searched for using a voltammetric hollow-fiber dialysis sensor via square wave stripping voltammetry (SW) , cyclic voltammetry (CV) , and chronoamperometry. Under optimum parameters, the analytical results indicated linear working ranges of 50~400 mg/l CV and 10~80 μg/l SW within a 30-sec accumulation time. The analytical detection limit (S/N) was 6.0 μg/l. The developed method can be applied to in vivo tissues and in ex vivo toxicity assay, as well as to other materials that require chromium analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gas Sensor Based on Large Hollow-Core Photonic Bandgap Fiber

One concern in using photonic band-gap fiber (PBGF) as a gas sensor is the response time. In this type of the gas sensors, response time is the time required for gas to diffuse into the hollow-core. So considering a large hollow-core PBGF (HC-PBGF), the response time can be significantly reduced. But in the large HC-PBGF, the fundamental issue is the presence of higher order modes (HOMs). Somet...

متن کامل

Disposable single-use electrochemical sensor: A novel hollow fiber based tool for environmental monitoring of cadmium

The objective of this study is to design a simple, fast, sensitive and single-use electrode with the simultaneous capability of preconcentration and measuring, for application in a three-electrode voltammetry system to identify and measure the heavy metal cadmium. The design process of this sensor consists of several stages. The polyurethane foam and multi walled carbon nanotubes nanoparticles ...

متن کامل

Development of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design

In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...

متن کامل

In-situ preconcentration, and electrochemical sensing of zinc(II) and copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology

A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane was divided into pieces of 2 c...

متن کامل

In-situ preconcentration, and electrochemical sensing of Zinc(II) and Copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology

A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane divided into pieces of 2 cm, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2010