Four-factor prothrombin complex concentrate versus plasma for rapid vitamin K antagonist reversal in patients needing urgent surgical or invasive interventions: a phase 3b, open-label, non-inferiority, randomised trial.
نویسندگان
چکیده
BACKGROUND Rapid reversal of vitamin K antagonist (VKA)-induced anticoagulation is often necessary for patients needing urgent surgical or invasive procedures. The optimum means of VKA reversal has not been established in comparative clinical trials. We compared the efficacy and safety of four-factor prothrombin complex concentrate (4F-PCC) with that of plasma in VKA-treated patients needing urgent surgical or invasive procedures. METHODS In a multicentre, open-label, phase 3b randomised trial we enrolled patients aged 18 years or older needing rapid VKA reversal before an urgent surgical or invasive procedure. We randomly assigned patients in a 1:1 ratio to receive vitamin K concomitant with a single dose of either 4F-PCC (Beriplex/Kcentra/Confidex; CSL Behring, Marburg, Germany) or plasma, with dosing based on international normalised ratio (INR) and weight. The primary endpoint was effective haemostasis, and the co-primary endpoint was rapid INR reduction (≤1·3 at 0·5 h after infusion end). The analyses were intended to evaluate, in a hierarchical fashion, first non-inferiority (lower limit 95% CI greater than -10% for group difference) for both endpoints, then superiority (lower limit 95% CI >0%) if non-inferiority was achieved. Adverse events and serious adverse events were reported to days 10 and 45, respectively. This trial is registered at ClinicalTrials.gov, number NCT00803101. FINDINGS 181 patients were randomised (4F-PCC n=90; plasma n=91). The intention-to-treat efficacy population comprised 168 patients (4F-PCC, n=87; plasma, n=81). Effective haemostasis was achieved in 78 (90%) patients in the 4F-PCC group compared with 61 (75%) patients in the plasma group, demonstrating both non-inferiority and superiority of 4F-PCC over plasma (difference 14·3%, 95% CI 2·8-25·8). Rapid INR reduction was achieved in 48 (55%) patients in the 4F-PCC group compared with eight (10%) patients in the plasma group, demonstrating both non-inferiority and superiority of 4F-PCC over plasma (difference 45·3%, 95% CI 31·9-56·4). The safety profile of 4F-PCC was generally similar to that of plasma; 49 (56%) patients receiving 4F-PCC had adverse events compared with 53 (60%) patients receiving plasma. Adverse events of interest were thromboembolic adverse events (six [7%] patients receiving 4F-PCC vs seven [8%] patients receiving plasma), fluid overload or similar cardiac events (three [3%] patients vs 11 [13%] patients), and late bleeding events (three [3%] patients vs four [5%] patients). INTERPRETATION 4F-PCC is non-inferior and superior to plasma for rapid INR reversal and effective haemostasis in patients needing VKA reversal for urgent surgical or invasive procedures. FUNDING CSL Behring.
منابع مشابه
Safety of a Four‐factor Prothrombin Complex Concentrate Versus Plasma for Vitamin K Antagonist Reversal: An Integrated Analysis of Two Phase IIIb Clinical Trials
OBJECTIVES Clinicians often need to rapidly reverse vitamin K antagonists (VKAs) in the setting of major hemorrhage or urgent need for surgery. Little is known about the safety profile of the traditional reversal agent, plasma, or the newly approved agent, four-factor prothrombin complex concentrate (4F-PCC), in a randomized setting. This is an integrated analysis of safety data from two clinic...
متن کاملEfficacy and safety of a 4-factor prothrombin complex concentrate in patients on vitamin K antagonists presenting with major bleeding: a randomized, plasma-controlled, phase IIIb study.
BACKGROUND Patients experiencing major bleeding while taking vitamin K antagonists require rapid vitamin K antagonist reversal. We performed a prospective clinical trial to compare nonactivated 4-factor prothrombin complex concentrate (4F-PCC) with plasma for urgent vitamin K antagonist reversal. METHODS AND RESULTS In this phase IIIb, multicenter, open-label, noninferiority trial, nonsurgica...
متن کاملFour-Factor Prothrombin Complex Concentrate Reduces Time to Procedure in Vitamin K Antagonist-Treated Patients Experiencing Gastrointestinal Bleeding: A Post Hoc Analysis of Two Randomized Controlled Trials
INTRODUCTION To investigate the impact of a 4-factor prothrombin complex concentrate (4F-PCC [Beriplex®/Kcentra®]) versus plasma on "time to procedure" in patients with acute/severe gastrointestinal bleeding requiring rapid vitamin K antagonist (VKA) reversal prior to invasive procedure. METHODS A post hoc analysis of two phase III trials of 4F-PCC versus plasma in patients with acute/severe ...
متن کاملIncreased risk of volume overload with plasma compared with four-factor prothrombin complex concentrate for urgent vitamin K antagonist reversal.
BACKGROUND Plasma is commonly used for vitamin K antagonist (VKA) reversal, but observational studies suggest that it is associated with transfusion-related adverse reactions (e.g., volume overload). However, this issue has not previously been addressed in a randomized controlled trial (RCT). STUDY DESIGN AND METHODS Factors associated with volume overload were examined using data from two Ph...
متن کاملRandomised controlled trial protocol to evaluate a fixed dose prothrombin complex concentrate against the variable dose in vitamin K antagonist related bleeding (PROPER3)
INTRODUCTION There is currently little evidence for the optimal dosing strategy of four-factor prothrombin complex concentrates (PCC) in vitamin K antagonist (VKA)-related bleeds. The generally accepted dosing strategy is the use of a variable dose calculated using patient-specific characteristics as per manufacturer's instruction. However, evidence exists that the use of a fixed low dose of 10...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lancet
دوره 385 9982 شماره
صفحات -
تاریخ انتشار 2015