Non-parametric geodesic active regions: Method and evaluation for cerebral aneurysms segmentation in 3DRA and CTA
نویسندگان
چکیده
Segmentation of vascular structures is a difficult and challenging task. In this article, we present an algorithm devised for the segmentation of such structures. Our technique consists in a geometric deformable model with associated energy functional that incorporates high-order multiscale features in a non-parametric statistical framework. Although the proposed segmentation method is generic, it has been applied to the segmentation of cerebral aneurysms in 3DRA and CTA. An evaluation study over 10 clinical datasets indicate that the segmentations obtained by our method present a high overlap index with respect to the ground-truth (91.13% and 73.31%, respectively) and that the mean error distance from the surface to the ground truth is close to the in-plane resolution (0.40 and 0.38 mm, respectively). Besides, our technique favorably compares to other alternative techniques based on deformable models, namely parametric geodesic active regions and active contours without edges.
منابع مشابه
Automated segmentation of cerebral vasculature with aneurysms in 3DRA and TOF-MRA using geodesic active regions: an evaluation study.
PURPOSE To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D x-ray reconstruction angiography (3DRA) and time of flight magnetic resonance angiography (TOF-MRA) images available in the clinical routine. METHODS Three aspects of the GAR method have been improved: ...
متن کاملGeodesic Active Regions Using Non-parametric Statistical Regional Description and Their Application to Aneurysm Segmentation from CTA
The inclusion of statistical region-based information in the Geodesic Active Contours introduces robustness in the segmentation of images with weak or inhomogeneous gradient at edges. The estimation of the Probability Density Function (PDF) for each region, involves the definition of the features that characterize the image inside the different regions. PDFs are usually modelled from the intens...
متن کاملThree-Dimensional Segmentation of Brain Aneurysms in CTA Using Non-parametric Region-Based Information and Implicit Deformable Models: Method and Evaluation
Knowledge of brain aneurysm dimensions is essential in minimally invasive surgical interventions using Guglielmi Detachable Coils. These parameters are obtained in clinical routine using 2D maximum intensity projection images. Automated quantification of the three dimensional structure of aneurysms directly from the 3D data set may be used to provide accurate and objective measurements of the c...
متن کاملDetection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography.
BACKGROUND AND PURPOSE Four-section multisection CT angiography (MSCTA) accurately detects aneurysms at or more than 4 mm but is less accurate for those less than 4 mm. Our purpose was to determine the accuracy of 64-section MSCTA (64MSCTA) in aneurysm detection versus combined digital subtraction angiography (DSA) and 3D rotational angiography (3DRA). MATERIALS AND METHODS In a retrospective...
متن کاملSixty-four-row multislice computed tomographic angiography in the diagnosis and characterization of intracranial aneurysms: comparison with 3D rotational angiography.
BACKGROUND Sixty-four-row multislice computed tomographic angiography (CTA) has great potential for use in vascular studies. The aim of our study was to compare 64-slice CTA with three-dimensional rotational angiography (3DRA) in the detection and characterization of intracranial aneurysms with special attention to smaller (<3-mm) aneurysms. METHODS In a prospective study, a total of 133 pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image analysis
دوره 11 3 شماره
صفحات -
تاریخ انتشار 2007