Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound
نویسندگان
چکیده
BACKGROUND Previously was found that sonography is a reliable method to measure a capsular distance in total hip arthroplasty hips. The aim of our current study was to investigate the relation between the implanted size of the cup and the anterior capsular distance, as measured with ultrasound one year after THA. METHODS 50 osteoarthritis (OA) patients operated on with total hip arthroplasty one year before were included in the study and the anterior capsular distance was measured sonographically. Patients were grouped with respect to cup size. The correlation between the implanted cup size and capsular distance was determined. RESULTS The mean capsular distance in the whole group was 1.37 (SD 0.19) cm. The mean capsular distance in the group with small cups was 1.27 (SD 0.13) cm, in large cups it was 1.45 (SD 0.20) cm, p = 0.02. Spearman correlation analysis showed a statistically significant correlation between a greater capsular distance and the larger size of the cup (r = 0.5, p < 0.0001). CONCLUSION The greater capsular distance in successful THA hips is affected by cup size. We propose that this should be considered when evaluating sonography of the anterior capsular distance after THA.
منابع مشابه
Navigated total hip arthroplasty using a 3-D freehand ultrasound system: technical note and preliminary results.
Ultrasound-navigated cementless total hip arthroplasty (THA) was performed in 10 consecutive patients with primary osteoarthritis of the hip between August 2008 and October 2009 (M:F, 6:4; median age, 61 years; age range, 30-86 years). The pelvic orientation was defined by preoperative digitization and registration of bony landmarks. Cup inclination and anteversion were documented for each pati...
متن کاملFunctional Mobility and Balance After Total Hip Arthroplasty and Healthy Elders
Objectives: The purpose of this study was to determine the functional mobility and balance in the elders after Total Hip Arthroplasty in healthy coparison to elders. Methods & Materials: The current cross-sectional study was done on 20 patients (70.9±4.2) with hip osteoarthritis 6 months after Total Hip Arthroplasty and 20 healthy subjects (73±5.7) as control group. Patient group was assigne...
متن کاملFluoroscopic imaging of acetabular cup position during THA through a direct anterior approach.
Mobile image intensifiers are more readily used to assess acetabular cup placement when performing a total hip arthroplasty through a direct anterior approach. However, patient positioning affects pelvic tilt and rotation, which in turn requires proper C-arm fluoroscopy adjustments for image interpretation. The authors provide insight into the interpretation of acetabular cup positioning based ...
متن کاملTrue Angle between Anterior-Posterior Impingement in Total Hip Arthroplasty: Why Common Constrained Cups have to Fail
Background: Dislocation after total hip arthroplasty is a common complication and partially based on impingement. Questions/purposes: (1) The purpose of this study was to investigate the angle between anterior and posterior impingement in current hip cup designs. (2) Furthermore, the aim was to design a model of an acetabular cup with sparing gaps that match to impact areas. Methods: The range ...
متن کاملPerioperative Comparison of Hip Arthroplasty Using the Direct Anterior Approach with the Posterolateral Approach
Purpose The aim of the current study is to report the advantage and disadvantage of total hip arthroplasty performed in direct anterior approach (DAA) by comparing it to the posterolateral approach (PLA). Materials and Methods Twenty-five hip arthroplasty done in DAA (12 total hip arthroplasty [THA] and 13 bipolar hemiarthroplasty [BHA]) were compared with the same number done in PLA (13 THA ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -