Principles of HeartMate II Implantation to Avoid Pump Malposition and Migration

نویسندگان

  • Robert M Adamson
  • Abeel A Mangi
  • Robert L Kormos
  • David J Farrar
  • Walter P Dembitsky
چکیده

Proper left ventricular assist device (LVAD) insertion will help maximize LVAD flow and may reduce adverse events such as right heart failure and pump thrombosis. Although no standardized insertion technique has been universally accepted, the goals are: unobstructed inflow cannula, unobstructed outflow graft with avoidance of right ventricular compression, and prevention of pump migration. To achieve these objectives for the HeartMate II LVAD, we delineate four principles: proper pump pocket creation, optimized positioning of inflow cannula and outflow graft, proper pump position in the body, and fixation. These basic principles are easy to implement and have been beneficial in our patients, assuring long-term unobstructed LVAD flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initial clinical experience with the HeartMate II axial-flow left ventricular assist device.

The redesigned HeartMate II, an axial-flow left ventricular assist device, is simpler, smaller, and easier to operate than are pulsatile pumps. These design characteristics should make the HeartMate II more reliable and durable and broaden the eligible population base. We implanted the HeartMate II in 43 patients (average age, 42 yr). The indication for use was bridge-to-heart transplantation i...

متن کامل

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...

متن کامل

Unexpected abrupt increase in left ventricular assist device thrombosis.

BACKGROUND We observed an apparent increase in the rate of device thrombosis among patients who received the HeartMate II left ventricular assist device, as compared with preapproval clinical-trial results and initial experience. We investigated the occurrence of pump thrombosis and elevated lactate dehydrogenase (LDH) levels, LDH levels presaging thrombosis (and associated hemolysis), and outc...

متن کامل

Reliability of the Thoratec HeartMate II flow measurements and alarms in the presence of reduced or non-existent flow.

INTRODUCTION The Thoratec Corporation has over 10,000 patients registered as recipients of the HeartMate II left ventricular assist device (LVAD) worldwide. Although it has undoubtedly prolonged the lifespan of heart failure patients, the most recognized risk associated with these devices is the development of thrombus. In the presence of a small or developing clot, the HeartMate II display mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2015