Laser lead extraction in the octogenarian patient.
نویسندگان
چکیده
BACKGROUND In the United States, patients aged >75 years are the most rapidly growing segment in the population, with an expected increase of 126% by 2050. These patients account for >70% of the pacemakers and up to two thirds of the implantable cardioverter-defibrillators implanted annually. Our aim was to explore the clinical outcomes of device complications in the octogenarian population. METHODS AND RESULTS We performed a retrospective chart review of 506 patients undergoing laser lead extraction from January 2004 to September 2009. This population was divided into the following 2 groups based solely on age: octogenarians and nonoctogenarians. These 2 groups were compared on the basis of several characteristics and clinical outcomes. There were 118 patients in the octogenarian group (78 men) and 388 in the nonoctogenarians group (301 men) aged 85±3.8 and 64.2±12.4 years, respectively. A total of 253 leads (atrial, 99; ventricular, 145; coronary sinus, 9) were removed from the patients in the octogenarian group, and 814 leads (atrial, 295; ventricular, 442; coronary sinus, 77) were removed from the patients in the nonoctogenarian group. The main indication for extraction for both groups was infection. The lead implant duration was 59.6±52.8 and 38.6±43.9 months for octogenarians and nonoctogenarians, respectively. There was no significant difference with respect to the proportion of minor (P=0.65), major (P=0.56), and total (P=0.50) complications. CONCLUSIONS Laser lead extraction is demonstrated to be a safe and effective treatment method in octogenarian patients with multiple comorbidities.
منابع مشابه
Percutaneous Extraction of ICD Lead Placed through a Persistent Left-Sided Superior Vena Cava with Right Superior Vena Cava Atresia
A 47 year old female with a history of non-ischemic cardiomyopathy and a defibrillator system presented for an infected ICD pocket site, two months after an elective generator change out. The patient was transferred to our institution after a failed lead extraction. During the index procedure, it was discovered she had the RV defibrillation lead implanted via a persistent left-sided SVC. During...
متن کاملA hybrid ICD extraction approach using laser and transfemoral extraction technique.
Indications for pacemaker and implantable cardioverter defibrillator (ICD) implantations are rapidly expanding. Hence, device-related complications have increased the need for lead extraction. Lead extractions are performed percutaneously or by open surgery. We present a patient with isolated left ventricular noncompaction cardiomyopathy suffering from ICD pulse generator pocket and lead infect...
متن کاملLaser assisted extraction of pacemaker and implantable defibrillator leads.
OBJECTIVE To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5+/-5.5 ye...
متن کاملPacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.
OBJECTIVES The purpose of this study was to evaluate the safety and effectiveness of pacemaker lead extraction with the excimer sheath in comparison to nonlaser lead extraction. BACKGROUND Fibrotic attachments that develop between chronically implanted pacemaker leads and to the venous, valvular and cardiac structures are the major obstacles to safe and consistent lead extraction. Locking sty...
متن کاملAn Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques
BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 4 5 شماره
صفحات -
تاریخ انتشار 2011