Pii: S1388-2457(99)00204-7
نویسندگان
چکیده
Objectives and methods: Mismatch negativities (MMN) to frequency and duration changes in a series of repetitive tones and to two different consonant-vowel syllables (ba and ga, standard da) were recorded in a test and retest session in 15 children aged 7±11 years. Reliability within one session and stability between the sessions of MMN amplitudes and the ERP-components P1 and N1 were determined by correlation coef®cients. Results: Mean amplitudes of the grand averages showed a decrease of MMN during the second test session in a late latency window (400± 500 ms) for the frequency MMN and of the MMN elicited by speech stimuli. The individual stability reached signi®cance only for the duration deviant and one of the syllables. Compared to results found in adults with similar stimulus conditions the stability of the MMN in children seems to be somewhat lower. The components P1 and N1 to both stimulus types (tone and speech), however, showed a high reliability and individual stability. Conclusion: While MMN is a useful tool to study processing de®cits in groups of children, as e.g. in language-impaired children, MMN as a individual diagnostic measure should be interpreted very cautiously. q 2000 Elsevier Science Ireland Ltd. All rights reserved.
منابع مشابه
Pii: S1388-2457(99)00005-x
About two-thirds of epilepsy patients who learn to control their slow cortical potential shifts (SCP) reduce their seizure rate, but the remaining third does not demonstrate clinical improvement. In the present study, this ®nding was replicated in a group of 27 patients with focal epilepsy. We found that patients who consistently produced larger negative SCP in all conditions during the ®rst ph...
متن کاملPii: S1388-2457(00)00527-7
Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10±20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is desc...
متن کاملPii: S1388-2457(02)00297-3
For algorithm developers, this review details recent approaches to the problem, compares the accuracy of various algorithms, identifies common testing issues and proposes some solutions. For the algorithm user, e.g. electroencephalograph (EEG) technician or neurologist, this review provides an estimate of algorithm accuracy and comparison to that of human experts. Manuscripts dated from 1975 ar...
متن کاملPii: S1388-2457(99)00011-5
Objectives: By using the Wavelet Transform, a time frequency representation with nearly optimal resolution, we studied responses to stimulation in the `alpha' range (10 Hz). Methods: Visual evoked responses of 10 healthy subjects were studied with 3 different stimulus types (no-task VEP, non-target and target stimulus). Results: Upon all the stimulus types, event-related responses in the 10 Hz ...
متن کاملPii: S1388-2457(98)00008-x
As opposed to slow waves, spontaneous and stimulus-induced oscillations in the gamma-band show no polarity reversal in cortical depth, which cannot be explained by the classical equivalent current dipole model usually proposed as a model of pyramidal cell synaptic activity. Here we propose a ring-shaped distribution of dipoles as a source model for these fast oscillations. This distribution gen...
متن کامل