Measuring right ventricular function in the normal and hypertensive mouse hearts using admittance-derived pressure-volume loops.
نویسندگان
چکیده
Mice are a widely used animal model for investigating cardiovascular disease. Novel technologies have been used to quantify left ventricular function in this species, but techniques appropriate for determining right ventricular (RV) function are less well demonstrated. Detecting RV dysfunction is critical to assessing the progression of pulmonary vascular diseases such as pulmonary hypertension. We used an admittance catheter to measure pressure-volume loops in anesthetized, open-chested mice before and during vena cava occlusion. Mice exposed to chronic hypoxia for 10 days, which causes hypoxia-induced pulmonary hypertension (HPH), were compared with control (CTL) mice. HPH resulted in a 27.9% increase in RV mass (P < 0.005), a 67.5% increase in RV systolic pressure (P < 0.005), and a 61.2% decrease in cardiac output (P < 0.05). Preload recruitable stroke work (PRSW) and slope of the maximum derivative of pressure (dP/dt(max))-end-diastolic volume (EDV) relationship increased with HPH (P < 0.05). Although HPH increased effective arterial elastance (E(a)) over fivefold (from 2.7 ± 1.2 to 16.4 ± 2.5 mmHg/μl), only a mild increase in the ventricular end-systolic elastance (E(es)) was observed. As a result, a dramatic decrease in the efficiency of ventricular-vascular coupling occurred (E(es)/E(a) decreased from 0.71 ± 0.27 to 0.35 ± 0.17; P < 0.005). Changes in cardiac reserve were evaluated by dobutamine infusion. In CTL mice, dobutamine significantly enhanced E(es) and dP/dt(max)-EDV but also increased E(a), causing a decrease in E(es)/E(a). In HPH mice, slight but nonsignificant decreases in E(es), PRSW, dP/dt(max)-EDV, and E(a) were observed. Thus 10 days of HPH resulted in RV hypertrophy, ventricular-vascular decoupling, and a mild decrease in RV contractile reserve. This study demonstrates the feasibility of obtaining RV pressure-volume measurements in mice. These measurements provide insight into ventricular-vascular interactions healthy and diseased states.
منابع مشابه
Conductance, admittance, and hypertonic saline: should we take ventricular volume measurements with a grain of salt?
UNDOUBTEDLY THE MOST COMPREHENSIVE way to assess contractile function of the heart relies on pressure-volume relationships, often called pressure-volume loops. Originally established in the canine model by Sagawa and coworkers, pressure-volume relationships allow us to determine indexes of ventricular performance that are independent of loading conditions and heart rate such as preload-recruita...
متن کاملEffects of Short-term Renovascular Hypertension and Type 2 Diabetes on Cardiac Functions in Rats
Background: The cardiac effects simultaneously occurring during experimental hypertension and diabetes have rarely been investigated. This study aimed at examining the effects of short-term renovascular hypertension and type 2 diabetes on cardiac functions. Methods: Five groups (7 each) of male Sprague-Dawley rats, including a control group, a diabetes (induced by Streptozocin and Nicotinamide)...
متن کاملA bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.
This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. There are two main advantages of the admittance technique to measure volume. First...
متن کاملNormal Value of Left Ventricular End-Systolic Elastance in Infants and Children
Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance. Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...
متن کاملDOPPLER-DERIVED RIGHT VEN T RICU L AR MYOC ARD IAL PERFORMANCE IN DEX IN NEON ATES: N ORMAL VALUES
Doppler-derived myocardial performance index (MPI) , defined as the s um of isovolumetric contraction and relaxation durations divided by ejection time, is an easily measured and reproducible index that shows both systolic and diastolic myocardial function. The goal of this study was to define normal values of right ventricular MPI in neonates in the first 48 to 72 hours of life. Fifty-one...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 299 6 شماره
صفحات -
تاریخ انتشار 2010