Dioxin analysis in water by using a passive sampler and CALUX bioassay.
نویسندگان
چکیده
Passive sampling of organic pollutants is a new trend in environmental monitoring and analysis. Passive samplers are being developed to overcome the drawbacks of the conventional snapshot sampling approach. The ceramic toximeter is a promising passive sampler for monitoring dioxin-contaminated surface and ground waters. It consists of an alumina cylinder lined with a thin coating of titania and a pore diameter of 0.05 μm. The cylinder serves as a diffusion barrier limiting the analyte transport to molecular diffusion only, as well as a container for a selective trapping material of a high capacity and affinity towards the chemical(s) of concern. The cylinder is closed from both sides with PTFE caps. The ceramic toximeter was filled with activated carbon as the trapping material and has been tested in vitro for the sampling of dioxin-contaminated water. In addition, the utilization of the CALUX bioassay technique for analyzing the trapped dioxin has greatly reduced the time and costs for dioxin scanning in aqueous media. Exposure times varied between 1 and 7 days in a solution of 1.35 ng-TCDDL(-1) (TCDD is 2,3,7,8-tetrachlorodibenzodioxin). The mean effective molecular diffusion coefficient of TCDD in the toximeter amounts to 11.9×10(-6)m(2)d(-1) while the minimum concentration detectable in an aquatic system after 30 days of exposure amounts to 0.89 pg-TCDDL(-1).
منابع مشابه
Time-integrated monitoring of dioxin-like polychlorinated biphenyls (dl-PCBs) in aquatic environments using the ceramic toximeter and the CALUX bioassay.
Ceramic passive samplers or toximeters (packed with active carbon 1%, w/w, on celite), in combination with the CALUX bioassay have been used as a time-integrated monitoring technique for dissolved dioxin-like PCBs in urban and industrial wastewaters. The technique showed to be reliable during laboratory experiments: (1) PCB-126 amounts extracted from the passive samplers increased linearly with...
متن کاملChemically activated luciferase gene expression (CALUX) cell bioassay analysis for the estimation of dioxin-like activity: critical parameters of the CALUX procedure that impact assay results.
The chemically activated luciferase gene expression (CALUX) in vitro cell bioassay is a bioanalytical tool that is increasingly being used by research and commercial laboratories for the screening and relative quantification of dioxins and dioxin-like compounds in sample extracts. Since CALUX analyses provide a biological response to all aryl hydrocarbon receptor active compounds present in a g...
متن کاملAnalysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples from the Flemish measurement network: correlation between the CALUX bioassay and GC-HRMS.
Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast, sensitive and inexpensive tool for the analysis of a high number of samples, the use of this technique in routine analysis of atmospheric deposition samples may be a valuable alternative for GC-HRMS. In this study, a validated CALUX method was used for the analysis of PCDD/Fs and dioxin-like PCBs in more than ...
متن کاملBio/chemical analysis of dioxin-like compounds in sediment samples from Osaka Bay, Japan.
The combinatorial bio/chemical investigation of sediments (six surface samples and one core sample) from Osaka Bay, Japan was conducted to clarify the horizontal and vertical distribution profiles of persistent organic pollutants in the sediments. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polybrominated dibenzo-p-dioxins a...
متن کاملThird-generation Ah receptor-responsive luciferase reporter plasmids: amplification of dioxin-responsive elements dramatically increases CALUX bioassay sensitivity and responsiveness.
2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD, dioxin) and related dioxin-like chemicals are widespread and persistent environmental contaminants that produce diverse toxic and biological effects through their ability to bind to and activate the Ah receptor (AhR) and AhR-dependent gene expression. The chemically activated luciferase expression (CALUX) system is an AhR-responsive recombinant lucifer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 88 شماره
صفحات -
تاریخ انتشار 2012