Comparative evaluation of three assay systems for automated determination of hemoglobin A1c.
نویسندگان
چکیده
We evaluated three newly introduced systems for automated determinations of hemoglobin (Hb) A1c, which allow the processing of large amounts of samples in a routine clinical laboratory. We compared these methods--the Variant HPLC, the Hi-Auto A1c analyzer system, and the Roche immunoassay--with the Diamat HPLC system. All showed good precision and good concordance with the Diamat HPLC. The reference range for Hb A1c has to be determined by the laboratory for each assay system. Interference study showed no statistically significant influence of anemia, polycythemia, rheumatoid factor, or chronic hemodialysis, although individual Hb A1c values can be influenced by polycythemia (when measured with the Hi-Auto A1c analyzer) and by chronic hemodialysis (when measured with the Variant HPLC). HPLC was not suitable for measuring Hb A1c in the examined cases of hemoglobin variants; assaying fructosamine seems to be better for monitoring these patients.
منابع مشابه
Evaluation of a nucleic acid-based cross-linking assay to screen for hereditary hemochromatosis in healthy blood donors.
14. 13. Chung BH, Segrest JP, Ray MJ, Brunzell JD, Hokanson JE, Krauss RM, et al. Single vertical spin density gradient ultracentrifugation. Methods Enzymol 1986;128:181–209. 14. Khuu HM, Robinson CA, Goolsby K, Hardy RW, Konrad RJ. Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c. Arch Pathol Lab Med 1999;123:763–7. 15. Khuu HM, Robinson CA, Briss...
متن کاملCorrelation between Standard Clinical Chemistry and Point of Care Testing Analyzers on Hemoglobin A1C Determination
متن کامل
An automated "high-pressure" liquid-chromatographic assay for hemoglobin A1c.
An automated "high-pressure" liquid-chromatographic assay for hemoglobin A1c is described. We use a 45-min incubation in acetate buffer (pH 5.5) to eliminate labile glycated hemoglobins. In this automated system conventional modules are used but it incorporates a solvent-switching valve to select either of two buffers, which differ in pH and NaCl concentration. The chromatographic column contai...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملHemoglobin A1c: Clinical applications and analytical considerations
Diabetes Mellitus (DM) is the most common disorder of carbohydrate metabolism. Hyperglycemia is the common feature of DM. Hyperglycemia causes cardiovascular, renal, ocular, and peripheral nerve disorders in patients with diabetes. Glycemic regulation plays an essential role in controlling these complications. Thus, evaluation of the glycemic control status is crucial in the management of DM. H...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 43 3 شماره
صفحات -
تاریخ انتشار 1997