An amperometric D-amino acid biosensor prepared with a thermostable D-proline dehydrogenase and a carbon nanotube-ionic liquid gel.

نویسندگان

  • Yuji Tani
  • Yukiko Itoyama
  • Kenichi Nishi
  • Chikahiro Wada
  • Yoshio Shoda
  • Takenori Satomura
  • Haruhiko Sakuraba
  • Toshihisa Ohshima
  • Yukako Hayashi
  • Tomoki Yabutani
  • Junko Motonaka
چکیده

Carbon nanotube (CNT) gel, which is composed of a mixture of single-wall CNT, an ionic liquid, and a thermostable D-proline dehydrogenase (D-Pro DH) immobilized electrode was utilized for the determination of D-amino acids (DAAs) in food samples. When a critical comparison with CNT, Ketjen Black (KB), and carbon powder (CP) was also carried out, the CNT/D-Pro DH immobilized electrode showed the highest sensitivity and the lowest detection limit of D-proline. In addition, the CNT/D-Pro DH immobilized electrode was applied to detection of DAAs in rice wine and vinegar samples. The concentrations of DAAs in rice wine and vinegar samples were 0.0210 +/- 0.0001 and 0.55 +/- 0.05 mmol L(-1), respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Different Functionalized CNTs for Development of Choline Amperometric Biosensor

Choline oxidase (ChOx) was chosen as a model enzyme for evaluating the performance of CNTs’ functional groups for development of enzyme electrodes. CNTs were functionalized with carboxylic acid, amine or amide groups. Carboxylic acid, amine and amide functionalized CNTs were obtained by acid treatment, ethylenediamine or tetraethylenepentamine chemically modification and ammonia plasma treatmen...

متن کامل

Screen-printed amperometric biosensors for the rapid measurement of L- and D-amino acids.

Screen-printed three-electrode amperometric sensors incorporating L- and/or D-amino acid oxidase for the general purpose measurement of L- or D-amino acids is described. The working electrode incorporates rhodinized carbon, to facilitate hydrogen peroxide oxidation at a decreased operating potential, and immobilized enzyme. The devices responded to all 20 common L-amino acids and all of the D-a...

متن کامل

Amperometric ethanol biosensor based on poly(vinyl alcohol)-multiwalled carbon nanotube-alcohol dehydrogenase biocomposite.

A novel amperometric ethanol biosensor was constructed using alcohol dehydrogenase (ADH) physically immobilized within poly(vinyl alcohol)-multiwalled carbon nanotube (PVA-MWCNT) composite obtained by a freezing-thawing process. It comprises a MWCNT conduit, a PVA binder, and an ADH function. The measurement of ethanol is based on the signal produced by beta-nicotinamide adenine dinucleotide (N...

متن کامل

Amperometric Low-Potential Detection of Malic Acid Using Single-Wall Carbon Nanotubes Based Electrodes

The electrocatalytical property of single-wall carbon nanotube (SWNT)modified electrode toward NADH detection was explored by cyclic voltammetry andamperometry techniques. The experimental results show that SWNT decrease theovervoltage required for oxidation of NADH (to 300 mV vs. Ag/AgCl) and this propertymake them suitable for dehydrogenases based biosensors. The behavior of the SWNTmodified ...

متن کامل

Investigation of Volumetric and Acoustic Properties of Ionic Liquid + Amino Acid + Water Systems at Different Temperatures

This paper reports density and speed of sound data for solutions of the ionic liquids (ILs) [C4mim]Cl and [C4mim][CF3SO3] in aqueous solution of 0.05 w/w amino acids of alanine, serine and proline at T = (288.15, 298.15, 308.15 and 318.15) K. From the experimental data measured, the apparent molar volume (Vϕ), isentropic compressibility ( ), and apparent molar isentropic compression ( ) have be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 2009