High-spatial Resolution Observations of a Small -spot

نویسنده

  • C. DENKER
چکیده

The Big Bear Solar Observatory (BBSO) has a long tradition of are observations. In this letter, we would like to direct the reader's attention to observations of a small-spot which produced a moderate are activity characterized by 18 C-class and 2 M-class ares. Active region NOAA 8076 (BBSO 3877) was one of the rst active regions in the new Solar Cycle No. 23. We present high spatial resolution white-light observations obtained on August 31st, 1997 with the speckle masking technique (Weigelt 1977; Weigelt & Wirnitzer1983; Lohmann et al. 1983). Almost diiraction limited speckle reconstructions revealed the complex and highly dynamical behavior of a small emerging-connguration in the central part of NOAA 8076. We found strong shear ows and indications of strong transverse elds in the small-spot. The are-producing mechanism for this small activity complex was very similar to that of the outstanding are-producing region NOAA 5395 of March 1989 (Wang et al. 1991), however, on a completely opposite spatial scale. As a by-product, the speckle interferometric techniques provided information about the seeing quality at a site. We used von der L uhe's (1984) spectral ratio technique to estimate the Fried-parameter r0. We measured a Fried-parameter of r0 = 9:0 0:7 cm and a maximum Fried-parameter of r max 0 = 10:3 cm indicating good seeing conditions during our observations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT

Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...

متن کامل

The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner

Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Fusion of LST products of ASTER and MODIS Sensors Using STDFA Model

Land Surface Temperature (LST) is one of the most important physical and climatological  crucial yet variable parameter in environmental phenomena studies such as, soil moisture conditions, urban heat island, vegetation health, fire risk for forest areas and heats effects on human’s health. These studies need to land surface temperature with high spatial and temporal resolution. Remote sensing ...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007