[Effects of tracheal tube cuff limit pressure (25 cmH2O) and "seal" pressure on tracheal mucosa of dogs.].

نویسندگان

  • Emanuel Celice Castilho
  • José Reinaldo Cerqueira Braz
  • Antonio José Maria Catâneo
  • Regina Helena Garcia Martins
  • Elisa Aparecida Gregório
  • Eduardo Raposo Monteiro
چکیده

BACKGROUND AND OBJECTIVES Injuries of tracheal mucosa in contact with tracheal tube cuff is a function of cuff pressure and exposure time. This study aimed at analyzing injuries of tracheal mucosa in contact with tracheal tube cuff inflated to reach "seal" pressure or limit 25 cmH2O pressure, below critical 30 cmH2O, to prevent tracheal damage. METHODS This study involved 16 dogs submitted to intravenous anesthesia and artificial ventilation. Dogs were randomly distributed into two experimental groups according to tracheal tube cuff pressure (Portex Blue Line, UK): Gseal (n = 8) cuff with minimum "seal" pressure to prevent air leakage during artificial ventilation; G25 (n=8) cuff inflated to 25 cmH2O. Cuff pressure was measured with a digital manometer at the beginning of the experiment (control) and 60, 120 and 180 minutes later. Animals were sacrificed and tracheal mucosa areas adjacent to the tracheal tube cuff were biopsed by scanning electronic microscopy (SEM). RESULTS Mean cuff pressure was maintained between 24.8 and 25 cmH2O in G25 and between 11.9 and 12.5 cmH2O in Gseal. SEM changes were mild and not significantly different between groups (p > 0.30), with more severe injuries to tracheal areas in contact with the cuff as compared to areas adjacent or not to tracheal tube (p < 0.05). CONCLUSIONS In dogs under our experimental conditions, tracheal tube cuff inflation to 25 cmH2O limit or to "seal" pressure to prevent air leakage has determined minor injuries to the tracheal mucosa in contact with tracheal tube cuff, without significant differences between groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF CHANGE IN POSITION ON INTRATRACHEAL CUFF PRESSURE IN PATIENTS UNDERGOING SURGERY WITH GENERAL ANESTHESIA: A PROSPECTIVE ANALYTICAL STUDY

Background & Aims: Tracheal intubation with a cuffed tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent aspiration and leakage of air and anesthetic gases. Whereas over-inflation can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. This study aimed to evaluate ...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

بررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی

Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...

متن کامل

Efficiency of a mechanical device in controlling tracheal cuff pressure in intubated critically ill patients: a randomized controlled study

BACKGROUND Cuff pressure (P cuff) control is mandatory to avoid leakage of oral secretions passing the tracheal tube and tracheal ischemia. The aim of the present trial was to determine the efficacy of a mechanical device (PressureEasy®) in the continuous control of P cuff in patients intubated with polyvinyl chloride (PVC)-cuffed tracheal tubes, compared with routine care using a manometer. ...

متن کامل

Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects

INTRODUCTION The inflation pressure of the endotracheal tube cuff can cause ischemia of the tracheal mucosa at high pressures; thus, it can cause important tracheal morbidity and tracheal microaspiration of the oropharyngeal secretion, or it can even cause pneumonia associated with mechanical ventilation if the pressure of the cuff is insufficient. OBJECTIVE In order to investigate the effect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 53 6  شماره 

صفحات  -

تاریخ انتشار 2003