Cementless total hip replacement: past, present, and future

نویسندگان

  • Harumoto Yamada
  • Yasuo Yoshihara
  • Osamu Henmi
  • Mitsuhiro Morita
  • Yuichiro Shiromoto
  • Tomoki Kawano
  • Arihiko Kanaji
  • Kennichi Ando
  • Masato Nakagawa
  • Naoto Kosaki
  • Eiichi Fukaya
چکیده

Cementless total hip replacement (THR) is rapidly being accepted as the surgery for arthritic diseases of the hip joint. The bone-ingrowth rate in porous-type cementless implants was about 90% over 10 years after surgery, showing that biological fixation of cementless THR was well maintained on both the stem and cup sides. As for the stress shielding of the femur operated using a distal fixation-type stem, severe bone resorption was observed. The severe bone resorption group showed continuous progression for more than 10 years after surgery. Stem loosening directly caused by stress shielding has been considered less likely; however, close attention should be paid to bone resorption-associated disorders including femoral fracture. Cementless cups have several specific problems. It is difficult to decide whether a cup should be placed in the physiological position for the case of acetabular dysplasia by bone grafting or at a relatively higher position without bone grafting. The bone-ingrowth rate was lower in the group with en bloc bone grafting, and the reactive line was frequently noted in the bone-grafted region. Although no data indicated that en bloc bone grafting directly led to poor outcomes, such as loosening, cup placement at a higher site without bone grafting is now selected by most operators. The polyethylene liner in a cementless cup is thinned due to the metal cup thickness; however, it has been suggested that the apparent relation between the cup size and the wear rate was absent as long as a cementless cup is used. Comparative study indicated cementless THR was inferior with regard to the yearly polyethylene wear rate and incidence of osteolysis on both the stem and cup sides. Meta-analysis study on the survival rate between cement and cementless THR reported that cemented THR was slightly superior. It should be considered that specific problems for cementless THR, especially with regard to polyethylene wear, do occur.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

[Total hip replacement in patients with ankylosing spondylitis.].

The authors present their experience with total hip replacement in patients with ankylosing spondylitis. In the period of 1985-1997 they performed in total 66 total hip replacements in 41 patients. Of the total number of the used implants 24 were fully cemented (the average follow-up - 13 years), 3 were hybrid and 39 cementless (the average follow-up - 6 years). The results of total hip replace...

متن کامل

Knee and Hip Joint Replacement Surgery in a Patient with Ochronotic Arthropathy: Surgical Tips

Ochronosis or black joints disorder is a rare autosomal recessive disorder caused by deficiency of homogentisic acidoxidase. Orthopaedic manifestations are common and mostly involve spine and large joints such as knee and hip.Arthropathy is progressive and will eventually leads to arthroplasty. Not being familiar with this disorder might lead todevastating complications. We present a 57 year-ol...

متن کامل

Results of 3,668 primary total hip replacements

BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Orthopaedic Science

دوره 14  شماره 

صفحات  -