Thermal processes for lead removal from the funnel glass of CRT monitors

نویسندگان

  • Hugo Marcelo Veit
  • Erich de Oliveira
  • Guilherme Richter
چکیده

The disposal of CRT monitors increases each year, generating millions of tons of waste containing various types of materials. The glass present in CRT tubes displayed about 20%–25% of lead oxide. If improperly disposed of, this glass can be leached directly in nature or may cause environmental contamination, especially with lead. Because of this leaching possibility, this waste is classified as Class I solid waste, according to the NBR 10004. Thermal processing of these glass tubes was seen as an alternative to remove lead from the glass matrix. Parameters such as reaction time, percentage of reducing agent, the reaction temperature, and atmospheric environment of the system were analyzed in this work. It was concluded that it is possible to remove the lead from the glass matrix by thermal processing. The removal of 92% of the lead from the glass was obtained at 800°C, a vacuum of 1.3 kPa, with 5% carbon as a reducing agent, and 18 hours of thermal processing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of lead oxide nanoparticles from cathode-ray tube funnel glass by self-propagating method.

This paper presents a novel process of extracting lead oxide nanoparticles from cathode-ray tube (CRT) funnel glass using self-propagating high-temperature synthesis (SHS) method. The impacts of added amount of funnel glass on the extraction ratio of lead, the lead extraction velocity and the micromorphology, as well as particle size of extracted nanoparticles were investigated. We found that s...

متن کامل

Thermogravimetric Investigation of the Lead Volatilization from Waste Cathode-Ray Tube Glass

The treatment of lead-containing cathode-ray tube (CRT) glass is an important environmental issue. One approach is the removal of lead by chloride volatilization. In the present work, the reaction of CRT glass with PVC as the chlorinating agent and Ca(OH)2 as the chlorine absorber was investigated by thermogravimetric analysis (TGA) in air. Seven reaction steps occurring at different temperatur...

متن کامل

Removal of lead from cathode ray tube funnel glass by chloride volatilization

Cathode ray tube funnel glass is an environmentally problematic relict of old television sets. In particular, landfilling of this material is strongly discouraged because of its high lead content. However, recovery of this toxic lead could prevent its release into the environment and allow its reuse. In this research, lead was separated from the glass matrix by a chloride volatilization process...

متن کامل

Oil Refinery Wastewater Treatment by Advanced Oxidation Processes for Chemical Oxygen Demand Removal using the Box-Behnken Method

This study investigated the reduction of the chemical oxygen demand from the Kermanshah oil refinery wastewater using Fenton and Photo-Fenton processes. The study investigated the effects of operating variables such as ultraviolet light intensity in values of 0, 15, and 30 W, ferrous ion concentration in values of 10, 50, and 90 mg/l, hydrogen peroxide concentration in values of 100, 500 and, 9...

متن کامل

Cathode Ray Tube (crt) Lead Glass: Lead Leaching Study after a Chelating Agent Treatment

This study is focused on the removal of leachable lead present in CRT (cathode ray tube) glass employing different chelating agents, NTA (nitrilotriacetic acid) and ATMP (amino trimetilen phosphonic acid), and then on the evaluation of their extractive capability. The operating conditions are the following: T=80°C, t=1h, pH=10, solid/liquid weight ratio=1/10, reagent concentration= 0.1 M. After...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015