Basic principles of computed axial tomography.
نویسنده
چکیده
Computer tomography (CT) is a radiological imaging method which yields transverse tomographic images reflecting with high accuracy the spatial distribution of x-ray attenuation in the part examined. The contrast resolution achieved by CT permits the visualization of soft tissue structure heretofore invisible with conventional radiographic procedure. The CT image is reconstructed by a computer applied algorithm, from a series of x-ray attenuation measurements obtained at different angles around the subject, by means of radiation detectors; The signal to noise ratio for these measurements is optimized by reducing the contribution of scattered radiation and of system noise. The CT principle of image reconstruction is also applicable in nuclear medicine imaging, with the goal of achieving contrast improvement and quantitative assessment of radionuclide distribution over conventional "projection" techniques. In this application, however, the attenuation of the radiation in the tissue interposed between the radionuclide and the detector must be taken into account to yield quantitatively accurate images. Furthermore, the variation of the field of view of the collimator as a function of distance contributes another unwanted variable to the reconstruction process. A mathematically rigorous tomographic reconstruction which would account for these variables is unavailable for gamma ray-emitting radionuclides, although approximate solutions of that problem have led to the satisfactory images of the head. Images of larger inhomogeneous organs are less quantitative. The detection of coincidence annihilation counting of positron-emitting radionuclides allows the accurate correction for the attenuation of that radiation in tissues and permits depth independent collimation which renders these radionuclide particularly suitable for their imaging by CT. A number of CT devices designed for the imaging of positron emitting radionuclides are yielding nuclear medicine images of quality and potential clinical usefulness unequaled by more conventional projection techniques.
منابع مشابه
Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملAssessment of Cone-Beam Computed Tomography (CBCT) Findings in Facial Asymmetric Patients
Introduction: Due to the complexity of facial asy-mmetry, the diagnosis of different aspects of asymmetry via conventional radiographs is not precise. In this study, we investigated findings of facial asymmetry by using cone- beam computed tomography (CBCT) images. Materials and Methods: In this descriptive study, we evaluated CBCT findings of 18 patients i.e. a group of 14 females and 4 males ...
متن کاملAnatomic variations of sphenoid sinus from Cone Beam Computed Tomography images in the Iranian population
Aims: Sphenoid sinus is one of the most inaccessible paranasal sinus, and is closely correlated to many vascular and neural structures. Anatomic variation of the sphenoid sinus can complicate surgery in this area. The aim of the present investigation was to define the sphenoid sinus variations and the relevant structures using cone-beam computed tomography (CBCT). Methods: This cross-sectiona...
متن کاملAnatomic Reference for Computed Tomography of the Paranasal Sinuses and Their Openings in the Rayini Goat
Objective- to provide a reference anatomy of the paranasal sinuses of the goat by using computed tomographic modality. Design- Experimented study. Animals- Five male Rayini goats. Procedures- CT images were acquired from the head region perpendicular to the hard palate. CT windows were adjusted as necessary to obtain the optimal image for the paranasal sinuses. The images were studie...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Seminars in nuclear medicine
دوره 7 2 شماره
صفحات -
تاریخ انتشار 1977