Validated HPAEC-PAD Method for the Determination of Fully Deacetylated Chitooligosaccharides
نویسندگان
چکیده
An efficient and sensitive analytical method based on high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) was established for the simultaneous separation and determination of glucosamine (GlcN)₁ and chitooligosaccharides (COS) ranging from (GlcN)₂ to (GlcN)₆ without prior derivatization. Detection limits were 0.003 to 0.016 mg/L (corresponding to 0.4-0.6 pmol), and the linear range was 0.2 to 10 mg/L. The optimized analysis was carried out on a CarboPac-PA100 analytical column (4 × 250 mm) using isocratic elution with 0.2 M aqueous sodium hydroxide-water mixture (10:90, v/v) as the mobile phase at a 0.4 mL/min flow rate. Regression equations revealed a good linear relationship (R² = 0.9979-0.9995, n = 7) within the test ranges. Quality parameters, including precision and accuracy, were fully validated and found to be satisfactory. The fully validated HPAEC-PAD method was readily applied for the quantification of (GlcN)1-6 in a commercial COS technical concentrate. The established method was also used to monitor the acid hydrolysis of a COS technical concentrate to ensure optimization of reaction conditions and minimization of (GlcN)₁ degradation.
منابع مشابه
Fully deacetylated chitooligosaccharides act as efficient glycoside hydrolase family 18 chitinase inhibitors.
Small molecule inhibitors against chitinases have potential applications as pesticides, fungicides, and antiasthmatics. Here, we report that a series of fully deacetylated chitooligosaccharides (GlcN)2-7 can act as inhibitors against the insect chitinase OfChtI, the human chitinase HsCht, and the bacterial chitinases SmChiA and SmChiB with IC50 values at micromolar to millimolar levels. The inj...
متن کاملA highly resolved anion-exchange chromatographic method for determination of saccharidic tracers for biomass combustion and primary bio-particles in atmospheric aerosol
An improved high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) method is developed and validated for simultaneous determination of atmospherically relevant sugar alcohols, monosaccharides, and monosaccharide anhydrides. The improved method enables the separation of levoglucosan and arabitol which were not or insufficiently separated by the previous H...
متن کاملNMR spectra of partially deacetylated chitotrisaccharides.
ucts contained a mixture of partially deacetylated chitooligosaccharides consisting of GlcNAc and GlcN.1'2* The structures of the partially deacetylated chito-oligosaccharides have been identified by a combination of Nacetylation, enzyme digestion, and nitrous acid degradation.^3) Recently, NMR spectroscopy has been usefully applied to a simpler and more definitive determination of oligosacchar...
متن کاملPreparation of chitooligosaccharides with degree of polymerization higher than 6 by acid or enzymatic degradation of chitosan
Chitosan was depolymerized either by HCl hydrolysis or enzymatic degradation with a commercial preparation Pectinex Ultra Spl. The chitooligosaccharides released by both methods were selectively precipitated in methanol solutions and characterized using MALDI-TOF mass spectrometry. Differences between the two methods were detected and concerned the degrees of polymerization of the fragments pro...
متن کاملA simple and rapid method for measuring α-D-phosphohexomutases activity by using anion-exchange chromatography coupled with an electrochemical detector
The interconversion of hexose-6-phosphate and hexose-1-phosphate can be directly analyzed by high-performance anion-exchange chromatography coupled with an electrochemical detector (HPAEC-PAD). Thus, this method can be used to measure the activities of N-acetylglucosamine-phosphate mutase (AGM), glucosamine-phosphate mutase (GlmM) and phosphoglucomutase (PGM), which are the members of α-D-phosp...
متن کامل