BACKGROUND Airway management out of the operating room in many major institutions is often performed by teams, requiring airway providers to carry their own materials at all times. The bag containing airway equipment must be light enough to be carried easily, while containing sufficient equipment to manage airways in various settings. Additionally, transport of the bag throughout the hospital raises concern about transmission of infection. We hypothesized that a new system of multiple, smaller bags would decrease weight, facilitate prompt location of equipment, and reduce the risk of bags acting as fomites. METHODS The service purchased small, nylon laryngoscope bags with dividers to keep equipment organized. The contents of the original bag and a new replacement bag were cataloged and both bags were weighed. Fourteen clinicians working on emergency airway consults at the time of the study were timed as they searched the bags for predetermined equipment with 2 scenarios and intubated a mannequin. The surfaces of the bags were swabbed for culture. RESULTS Clinicians were significantly faster to locate equipment with the new compared to the original bag, with a difference of 39 s (P < .001, 95% CI 19-58 s) in the first scenario, and 22 s (P < .001, 95% CI 13-32 s) in the second. The cultures from the original bag demonstrated coagulase-negative Staphylococcus, enterococcus, Bacillus species, alpha-hemolytic Streptococcus, non-hemolytic Streptococcus, and a Staphylococcus species of a second type. The culture of the new bag after clinical use but before cleaning grew rare Aspergillosis species. The culture of the new bag after undergoing proper cleaning demonstrated no growth. CONCLUSIONS Exchanging a large canvas bag for several smaller nylon bags has improved the transport of emergency airway equipment, with benefits in carrying the bag, locating equipment, and reducing the transport of pathogens throughout the hospital.
منابع مشابه
Survey of neonatal resuscitation equipment in emergency departments in the UK.
OBJECTIVE All emergency departments (EDs) should be adequately equipped and prepared to deal with unexpected neonatal deliveries and resuscitation. A study was undertaken to determine what neonatal resuscitation equipment is available in EDs in the UK and to formulate recommendations for improvement. METHODS A prospective telephone survey of all UK EDs was conducted between November 2008 and ...
متن کاملImproving the safety of remote site emergency airway management
Airway management, particularly in non-theatre settings, is an area of anaesthesia and critical care associated with significant risk of morbidity & mortality, as highlighted during the 4th National Audit Project of the Royal College of Anaesthetists (NAP4). A survey of junior anaesthetists at our hospital highlighted a lack of confidence and perceived lack of safety in emergency airway managem...
متن کاملTime Indicators of Pre-hospital Emergency Services in Ardabil, 2020
Objective: Considering the importance of the role and function of emergency medical services(EMS) in a society’s health and the need for continuously evaluating its function, especially in indices affecting the process of giving service to the patients, the present study was done with the aim of was to determine the time indicators of EMS in Ardabil. Materials &Methods: This study was a retro...
متن کاملPre-hospital advanced airway management by anaesthesiologists: Is there still room for improvement?
BACKGROUND Endotracheal intubation is an important part of pre-hospital advanced life support that requires training and experience, and should only be performed by specially trained personnel. In Norway, anaesthesiologists serve as Helicopter Emergency Medical Service HEMS physicians. However, little is known about how they themselves evaluate the quality and safety of pre-hospital advanced ai...
متن کاملComparison of direct laryngoscopy to Pediatric King LT-D in simulated airways.
OBJECTIVES Previous reports have shown a high rate of ventilation failure via direct laryngoscopy as compared with the King LT-D airway. This difference is further divergent in the pediatric population. The goal of this study was to compare the difference in efficacy of ventilation by prehospital providers in a simulated environment between direct laryngoscopy and Pedi-King LT-D. METHODS In t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 55 7 شماره
صفحات -
تاریخ انتشار 2010