Evaluation of a Newly Developed Lateral Flow Immunoassay for the Diagnosis of Cryptococcosis
نویسندگان
چکیده
BACKGROUND Cryptococcosis is a common opportunistic infection of human immunodeficiency virus (HIV)-infected individuals mostly occurring in resource-limited countries. This study compares the performance of a recently developed lateral flow immunoassay (LFA) to blood culture and enzyme immunoassay (EIA) for the diagnosis of cryptococcosis. METHODS Archived sera from 704 HIV-infected patients hospitalized for acute respiratory illness in Thailand were tested for cryptococcal antigenemia using EIA. All EIA-positive and a subset of EIA-negative sera were tested by LFA, with results recorded after 5 and 15 minutes incubation. Urine from patients with LFA- and EIA-positive sera was tested by LFA. Antigen results from patients with positive cryptococcal blood cultures were compared. RESULTS Of 704 sera, 92 (13%) were positive by EIA; among the 91 EIA-positive sera tested by LFA, 82 (90%) and 87 (96%) were LFA positive when read after 5 and 15 minutes, respectively. Kappa agreement of EIA and LFA for sera was 0.923 after 5 minutes and 0.959 after 15 minutes, respectively. Two of 373 EIA-negative sera were LFA positive at both time points. Of 74 urine specimens from EIA-positive patients, 52 (70.3%) were LFA positive. EIA was positive in 16 of 17 sera from blood culture-positive patients (94% sensitivity), and all sera were positive by LFA (100% sensitivity). CONCLUSIONS A high level of agreement was shown between LFA and EIA testing of serum. The LFA is a rapid, easy-to-perform assay that does not require refrigeration, demonstrating its potential usefulness as a point-of-care assay for diagnosis of cryptococcosis in resource-limited countries.
منابع مشابه
Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies
Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...
متن کاملCOVID-19; History, Taxonomy, and Diagnostic Molecular and Immunological Techniques
In recent years, viral epidemics such as the coronavirus disease (COVID-19) have spread, and this outbreak is thought to be the result of animal-to-human transmission. Hence, accurate diagnostic tests to detect COVID-19 and antiviral antibodies in infected individuals are of utmost importance. This report describes the structure, history, taxonomy, and molecular and immunological techniques for...
متن کاملMeasurement of Urinary N-Telopeptides and Serum C-Telopeptides from Type I Collagen Using a Lateral Flow-Based Immunoassay
Measuring bone turnover markers could detect early stages of osteoporosis and early responses to anti-osteoporotic treatments. Currently, commonly used bone turnover markers, N-telopeptides (NTx) and C-telopeptides (CTx), are measured using ELISA tests, which demands time and increases cost. Bone turnover markers need to be measured more easily for general use. Lateral flow-based immunoassay wo...
متن کاملEvaluation of a New Cryptococcal Antigen Lateral Flow Immunoassay in Serum, Cerebrospinal Fluid and Urine for the Diagnosis of Cryptococcosis: A Meta-Analysis and Systematic Review
BACKGROUND A new lateral flow immunoassay (LFA) for the detection of cryptococcal antigen was developed. OBJECTIVE We aimed to systematically review all relevant studies to evaluate the diagnostic accuracy of the cryptococcal antigen LFA on serum, CSF and urine specimens. METHODS We searched public databases including PubMed, Web of Science, Elsevier Science Direct and Cochrane Library for ...
متن کاملLateral flow immunoassay: Present status, trends and future perspective in diseases detection
This article has no abstract.
متن کامل