Determination of Nicotine in Tobacco by Chemometric Optimization and Cation-Selective Exhaustive Injection in Combination with Sweeping-Micellar Electrokinetic Chromatography

نویسندگان

  • Yi-Hui Lin
  • Chia-Hsien Feng
  • Shih-Wei Wang
  • Po-Yun Ko
  • Ming-Hsun Lee
  • Yen-Ling Chen
چکیده

Nicotine is a potent chemical that excites the central nervous system and refreshes people. It is also physically addictive and causes dependence. To reduce the harm of tobacco products for smokers, a law was introduced that requires tobacco product containers to be marked with the amount of nicotine as well as tar. In this paper, an online stacking capillary electrophoresis (CE) method with cation-selective exhaustive injection sweeping-micellar electrokinetic chromatography (CSEI-sweeping-MEKC) is proposed for the optimized analysis of nicotine in tobacco. A higher conductivity buffer (160 mM phosphate buffer (pH 3)) zone was injected into the capillary, allowing for the analytes to be electrokinetically injected at a voltage of 15 kV for 15 min. Using 50 mM sodium dodecyl sulfate and 25% methanol in the sweeping buffer, nicotine was detected with high sensitivity. Thus, optimized conditions adapted from a chemometric approach provided a 6000-fold increase in the nicotine detection sensitivity using the CSEI-sweeping-MEKC method in comparison to normal CZE. The limits of detection were 0.5 nM for nicotine. The stacking method in combination with direct injection which matrix components would not interfere with assay performance was successfully applied to the detection of nicotine in tobacco samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography to determine selective serotonin reuptake inhibitors.

We have employed a rapid and highly efficient on-line preconcentration method, cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-sweeping-MEKC), for the analysis of selective serotonin reuptake inhibitors (SSRIs) of antidepressant drugs. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations o...

متن کامل

Optimization of the separation of lysergic acid diethylamide in urine by a sweeping technique using micellar electrokinetic chromatography.

The separation and on-line concentrations of lysergic acid diethylamide (LSD), iso-lysergic acid diethylamide (iso-LSD) and lysergic acid N,N-methylpropylamide (LAMPA) in human urine were investigated by capillary electrophoresis-fluorescence spectroscopy using sodium dodecyl sulfate (SDS) as an anionic surfactant. A number of parameters such as buffer pH, SDS concentration, Brij-30 concentrati...

متن کامل

Determination of lysergic acid diethylamide (LSD) by application of online 77 K fluorescence spectroscopy and a sweeping technique in micellar electrokinetic chromatography.

The principal advantage of the use of Shopl'skii effect (low temperature spectrum) is that spectral sharpening occurs both in absorption and emission. However, thus far using the technique of capillary electrophoresis/low temperature fluorescence spectroscopy (CE/LTFS) either at 77 or 4.2 K remains difficult to obtain an on-line spectrum, if the analyte is present at low concentration. This pap...

متن کامل

Determination of corticosterone and 17-hydroxycorticosterone in plasma and urine samples by sweeping techniques using micellar electrokinetic chromatography.

The analysis of corticosterone in mouse blood serum (metabolic-stress experiment) and 17-hydroxycorticosterone in human urine (exercise-stress experiment) samples by means of capillary electrophoresis/UV absorbance in conjunction with online sample concentration techniques is described. The use of normal MEKC had an analyte detection limit of 7 microg/ml (S/N=3); whereas when online sample conc...

متن کامل

Determination of cypromazine and its metabolite melamine in milk by cation-selective exhaustive injection and sweeping-capillary micellar electrokinetic chromatography.

In this study, we described a high-sensitive on-line preconcentration method for cypromazine (CYP) and melamine (MEL) analysis using cation-selective exhaustive injection (CSEI) combined with sweeping-MEKC. The optimum conditions of on-line concentration and separation were discussed. The BGE contained 100 mM SDS, 50 mM phosphoric acid (pH=2.0) and 15% acetonitrile (v/v). The sample was injecte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015