Clinical Usability of a Wound Measurement Device

نویسندگان

  • Michelle Nemeth
  • Stephen Sprigle
  • Anita Gajjala
چکیده

Objective: Monitoring wound size is an integral component to the assessment and treatment of chronic wounds. Conventional methods, such as ruler measures and transparency tracings, for measuring wound size often have low accuracy and reliability. Newer high tech methods, while more reliable and accurate, are often expensive and difficult to use. The objective of the study was to design a wound measurement device (WMD) with the following features: ease of use, low cost, non-contact, time-saving, hand-held, reliable, and battery operated. Design: The performance of the WMD was evaluated in two rounds of bench testing for accuracy and reliability, followed by a single round of clinical testing to assess ease of use. Participants/Methods: Bench testing of the WMD was completed to assess for accuracy over distance from the wound surface, as well as camera angle skew. The performance in terms of interand intra-rater reliability was also assessed. Three clinicians participated in the clinical trial portion of the study. 45 subjects were recruited. General usability and ease of use was measured through the use of written surveys and verbal feedback from the participating clinicians. Results: Intra-rater reliability of presented images for which each clinician was asked to interpret and trace the wound exceeded 0.975. Inter-rater reliability of these same images was 0.966-0.978. Accuracy measures based on two black and white shapes with known areas had an average 2.65% error rate. Conclusions: Both intraand inter-rater reliability proved to be significantly higher than conventional methods, such as ruler measures and transparency tracings. The WMD was easy to use for the clinician. Support: This project was funded by NIDRR Wheeled Mobility RERC#H133030035, IP2Biz and CATEA. Key Words—wound measurement, pressure ulcer, chronic wounds, digital image processing, wound area

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iterative design and testing of a hand-held, non-contact wound measurement device.

A variety of wound measurement techniques are available to clinicians. Options range from relatively simple and inexpensive to complex, expensive devices. An iterative design approach was used to evaluate and improve performance and clinical utility of a new wound measurement device (WMD). The design was based upon a commercially available Smartphone. Accuracy was assessed using bench testing a...

متن کامل

Developing and Validating a New Wireless Wearable Device for Balance Measurement in Sport and Clinical Setting

One of the new clinical techniques to assess the lower body parameters is the wearable ultrasonic sensors. The device which can measure the static and dynamic balance abilities in sport and clinical setting by the traveled signals of ultrasonic transmitter and receiver between two feet was developed and validated. The new device consisted of a pressure gauge and a digital centimeter indicator a...

متن کامل

A Clinically Affordable Non-Contact Wound Measurement Device

In this paper we present a hand-held, clinically affordable, non-contact wound measurement device. The device was designed with ease of use in mind and to be capable of processing a single wound in under 1 minute. The current prototype is built on a Sony-Ericsson P900 phone and interfaces via Bluetooth with a laptop where the majority of data processing is done. The proposed final version of th...

متن کامل

A Lightweight App Distribution Strategy to Generate Interest in Complex Commercial Apps: Case Study of an Automated Wound Measurement System

Tablet-based healthcare technologies automating clinical triage procedures hold exciting promise for increased precision and expediency. These point-ofcare (POC) solutions are often complex, and their introduction to the marketplace may encounter cost and usability barriers. One example triage procedure is wound measurement. This paper demonstrates an innovative approach to POC wound measuremen...

متن کامل

Comparison of Pain, Wound Healing, Facial Edema, and Surgeon’s Comfort in Surgical Extraction of Impacted Third Molars: Surgical Scalpel Versus Radiofrequency Incision

Background and Aim: This study aimed to compare the level of pain, wound healing, facial edema, and surgeon’s comfort in surgical extraction of impacted third molars using surgical scalpel versus radiofrequency (RF) incision. Materials and Methods: This split-mouth clinical trial evaluated 41 patients with bilateral impacted third molars in one jaw with the same Pederson difficulty index (betw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010