DFT-based Synchrophasor Estimation Algorithms and their Integration in Advanced Phasor Measurement Units for the Real-time Monitoring of Active Distribution Network

نویسنده

  • Paolo ROMANO
چکیده

The increasing penetration of Distributed Energy Resources (DERs) at the low andmediumvoltage levels is determining major changes in the operational procedures of distribution networks (DNs) that are evolving from passive to active power grids. Such evolution is causing non-negligible problems to DN operators (DNOs) and calls for advanced monitoring infrastructures composed by distributed sensing devices capable of monitoring voltage and current variations in real-time. In this respect, PhasorMeasurement Units (PMUs) definitely represent one of themost promising technologies. Their higher accuracy and reporting rates compared to standard monitoring devices, together with the possibility of reporting time-tagged measurements of voltage and current phasors, enable the possibility to obtain frequent and accurate snapshots of the status of the monitored grid. Nevertheless, the applicability of such technology to DNs has not been demonstrated yet since PMUs where originally conceived for transmission network applications. Within this context, this thesis first discusses and derives the requirements for PMUs expected to operate at power distribution level. This study is carried out by analyzing typical operating conditions of Active Distribution Networks (ADNs). Then, based on these considerations, an advanced synchrophasor estimation algorithm capable of matching the accuracy requirements of ADNs is formulated. The algorithm, called iterative-interpolated DFT (i-IpDFT) improves the performances of the Interpolated-DFT (IpDFT) method by iteratively compensating the effects of the spectral interference produced by the negative image of the spectrum and at the same time allows to reduce the window length up to two periods of a signal at the nominal frequency of the power system. In order to demonstrate the low computational complexity of such an approach, the developed algorithm has been subsequently optimized to be deployed into a dedicated FPGA-based PMU prototype. The influence of the PMU hardware components and particularly the effects of the stability and reliability of the adopted UTC-time synchronization technology have been verified. The PMU prototype has been metrologically characterized with respect to the previously defined operating conditions of ADNs using a dedicated PMU calibrator developed in collaboration with the Swiss Federal Institute of Metrology (METAS). The experimental validation has verified the PMU compliance with the class-P requirements defined in the IEEE Std. C37.118 and with most of the accuracy requirements defined for class-M PMUs with the exception of out of band interference tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Presenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units

In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...

متن کامل

Algorithms and Performance Analysis for Synchrophasor and Grid State Estimation

The electrical quantities of future power networks are expected to exhibit strong fluctuations caused by dynamic bidirectional energy flows transferred from/to a multitude of “prosumers”. Such variations have to be accurately measured in real-time either for efficient power distribution or for safety and protection purposes. This task can be accomplished by the Phasor Measurement Units (PMUs), ...

متن کامل

Application of Phasor Measurement Unit in Smart Grid

A smart Grid uses two way digital communication with advanced sensors to collect and analyze data for transforming the existing electric grid into intelligent, dynamic selfhealing, self optimizing transmission and distribution grid . As critical grid events often require real-time recognition and real time response .A smart grid uses IP-based ,open standard, intelligent communication to measure...

متن کامل

Tracking State Estimation in Distribution Networks Using Distribution-level Synchrophasor Data

State estimation is often a challenging task in distribution systems due to numerous nodes and limited number of measurement sources. As a result, distribution system state estimation is often not real-time; instead, it is done once every 5 to 15 minutes, e.g., when smart meter measurements are available. Accordingly, this paper proposes a novel method for tracking state estimation in distribut...

متن کامل

Robust state estimation in power systems using pre-filtering measurement data

State estimation is the foundation of any control and decision making in power networks. The first requirement for a secure network is a precise and safe state estimator in order to make decisions based on accurate knowledge of the network status. This paper introduces a new estimator which is able to detect bad data with few calculations without need for repetitions and estimation residual cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016