A Rosetta stone for insulin treatment: self-monitoring of blood glucose.

نویسنده

  • William E Winter
چکیده

In the daily management of type 1 diabetes, self-monitoring of blood glucose (SMBG) is the recommended glycemic monitor, or “Rosetta stone”, that enables improved glycemic control (1 ). By measuring real-time glucose, informed patients can modify their diabetes management acutely or prospectively to sustain glucose in a narrow range near normal. A recent study from the Veterans Administration demonstrated improved glycemic control with lowered hemoglobin A1c in patients with insulintreated type 2 diabetes who performed SMBG (2 ). A wide range of insulins is now available with various durations of action that can help to improve glycemic control. The greatest therapeutic advances entail the use of recombinant DNA-engineered insulin analogs. Novel insulins such as lyspro-insulin [lysine(B28), proline(B29)] have a very rapid onset of action (15–30 min), peak effect (1–2 h), and limited overall duration of action (3–4 h), whereas glargine (-Gly-30a-l-Arg-30h-l-Arg-human) has no peak and a duration of action of 24 h or longer. Maintaining blood glucose at or very near the normal range decreases the frequency of new-onset microvascular complications and delays the progression of established microvascular complications in both type 1 and type 2 diabetes (3–5). In non-insulin-treated patients, before 2002 there were few data to suggest that SMBG improved clinical outcome (6 ). However a recent study from France found that SMBG lowered hemoglobin A1c in monitored, non-insulin-treated type 2 diabetes (7 ), as did a study from Germany (8 ). Accurate and precise blood glucose measurements are no doubt helpful and important to achieve optimal diabetic care (9 ). However, unless patients alter their care (e.g., acute adjustments in diet, exercise, or insulin dosing) in response to the real-time blood glucose or in anticipation of changes in blood glucose, even the most accurate and precise glucose measurement will not improve glycemic control. Simply put, knowledge of blood glucose, without patient action based on these data, will be ineffective in lowering the hemoglobin A1c concentration. The development of patient-care algorithms to normalize blood glucose is the responsibility of the physician and healthcare team providing care to the patient with diabetes (10 ). The responsibility of the laboratorian and the diagnostics industry is to ensure that blood glucose monitors provide accurate and precise measurements. One of the greatest fears of insulin-treated individuals is the development of hypoglycemia. This emphasizes the need for optimal low-end analytical performance. Severe untreated hypoglycemia can be deadly (11 ). In this issue of Clinical Chemistry, Kristensen et al. (12 ) provide a proposed procedure for “cost-reasonable” strip and meter evaluation ( $20 000/evaluation). Kristensen et al. remind us that patients do not perform SMBG as precisely as medical laboratory technologists. This is not a novel revelation (13 ); nonetheless, the documentation of this fact is worthwhile. The authors identify several factors that contribute to lower glucose precision in patients performing SMBG compared with medical laboratory technologists, including (a) higher rates of inadequate sample volume applied to the detection strip (i.e., difficulties with the physical delivery of blood to the strip), (b) failure of patients to further recognize inadequate sample delivery; and (c) meter coding errors by patients. It is refreshing to know that patient education does improve precision. Concerning factors outside the control of the patient, for one of the two analyzers evaluated, one of three lots of strips displayed reduced analytical performance. What can be done to further improve the analytical and daily performance of SMBG? The answers can be divided into technical improvements in the SMBG systems and improved patient education. The first recommendation taken from this Technical Brief (12 ) is that all strips and meters should have mechanisms to detect inadequate sample delivery. Regarding one of the two meters evaluated, the data indicated that almost one in four samples had an inadequate volume. To use a strip/meter system that does not detect adequate sample volume risks recurrent “short-sampling”. Furthermore, inadequate sample delivery does not guarantee a negative bias to the result [see the filled circles in Fig. 1 of Kristensen et al. (12 )]. Overestimation of blood glucose could lead to hypoglycemia from overtreatment, whereas underestimation of blood glucose could lead to hyperglycemia from undertreatment. Certainly other technologic improvements can be made in strip/monitor systems, such as a patient-lockout capacity if controls are not run and/or are out of range; alarms for short-sampling; simplification of sample loading; talking devices that advise the patient of errors; electronic controls that are run daily and provision of liquid controls that can be run weekly or more often; easier availability of data downloads to personal computers or the web for interface with the healthcare team; internal algorithms that could track current and past blood glucose readings, time of day, food intake, previous insulin doses, and exercise to provide recommended insulin adjustments; interfaces between the glucose meter and continuous subcutaneous insulin infusion pumps that regulate the rate and pattern of insulin infusion (i.e., an artificial pancreas); alarms that notify the patient that it is time to check blood glucose; and user-friendly keypads and displays designed for individuals with a limited education. Improving the analytical performance of the meter balances cost vs accuracy and precision. Better measuring devices and strips will likely be more expensive. However, if up to 25% of certain SMBG blood glucose results are “wasted” because of inadequate sample delivery or other technical failures, is it any bargain not to use the best systems available? Manufacturers caution that if Editorial

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-monitoring of blood glucose. American Diabetes Association.

Self-monitoring of blood glucose is an increasingly used adjunct to diabetes care. Meticulous technique for visual comparisons and reflectance meters are mandatory. The data collected in this manner must be used for therapeutic decisions if SMBG is to aid the person with diabetes. Self-monitoring of blood glucose, if prescribed by the physician, becomes part of routine clinical treatment for in...

متن کامل

Effect of Acute Morphine Exposure on Insulin and Blood Sugar Levels in Normal Rats

OBJECTIVE: Social belief and experimental evidences indicate that opium and its alkaloids, morphine, produced hypoglycemic effects in animal models. This study was conducted in order to determine the role of morphine on blood glucose and insulin. MATERIAL AND METHODS: This is an empirical analysis investigating the laboratory albino male rats weighing 200-250 g. Rats in the control group recei...

متن کامل

Meal-related structured self-monitoring of blood glucose: effect on diabetes control in non-insulin-treated type 2 diabetic patients.

OBJECTIVE To investigate the effect of meal-related self-monitoring of blood glucose on glycemic control and well-being in non-insulin-treated type 2 diabetic patients. RESEARCH DESIGN AND METHODS This 6-month study, which included 6 months of follow-up, adopted a prospective, multicenter, randomized controlled design. Subjects were randomized to two groups: one group used a blood glucose-mon...

متن کامل

تأثیر مداخله آموزشی مبتنی بر الگوی مراقبت پیگیر بر خودپایشی قند خون بیماران دیابتی نوع 2

Background and Aim: Appropriate control of blood sugar delays the onset and progression of diabetes mellitus (DM) complications. Nurses have a decisive role in the education of self-care behaviors to diabetic patients, including self-monitoring of blood glucose. The current study aimed at assessing the effect of educational intervention based on continuous care model on self-monitoring of blood...

متن کامل

In vivo evaluation of physiological efficacy of insulin-loaded nanoliposomes prepared for oral delivery

Introduction: Oral delivery is the most favorable route for insulin administration. The aim of this study was to generate new chitosan coated insulin nanoliposomes and then to assess the physiological efficacy of these nanoliposomes after oral administration in diabetic rabbits. Methods: Nanoliposomes with negative surface charge encapsulating insulin were prepared by reverse phase evaporat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 6  شماره 

صفحات  -

تاریخ انتشار 2004