Lead extraction using a laser system: Techniques, efficacy, and limitations
نویسنده
چکیده
Transvenous lead extraction is becoming popular in Japan since the approval of laser extraction system in 2010. The laser system seems to be the standard method used by most physicians, owing to its efficacy and ease of handling. The efficacy and safety of this technology has been well proven in many studies and the data suggest that it can be used for Japanese patients safely. However, lead extraction can cause serious complications. Thus, it is important to learn the limitations as well as the basic techniques and efficacy of this procedure.
منابع مشابه
Review of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملEfficacy of Diode Laser in unwanted hair removal
Background: Numerous lasers are currently available for hair removal. Objective: To study the efficacy of a pulsed diode laser for removing unwanted hair. Patients and Methods: In this quasi-experimental clinical trial, 39 patients with unwanted hairs on chin referred to Novin-Didegan Laser Center in Tehran were treated with a diode laser system (Palomar, 810nm). Fluences ranging from 40 to 64 ...
متن کاملAn Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques
BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...
متن کاملInitial experience in the extraction of chronically implanted pacemaker leads using the Excimer laser sheath.
OBJECTIVE To assess the safety and efficiency of the Excimer laser sheath in extracting chronically implanted pacemaker leads. PATIENTS Eight patients were studied (one female, mean age 62 years, range 34 to 77) with 17 pacemaker leads (five atrial, 10 ventricular, two implantable defibrillator). The mean implantation time was 65 months (range 23 to 188). The indications for lead extraction w...
متن کامل