Use of multidetector row CT to evaluate the need for bronchial arterial embolization in hemoptysis patients.

نویسندگان

  • Hidenori Mori
  • Yasushi Ohno
  • Yusuke Tsuge
  • Masanori Kawasaki
  • Fumitaka Ito
  • Junki Endo
  • Norihiko Funaguchi
  • Bu Lin Bai La
  • Masayuki Kanematsu
  • Shinya Minatoguchi
چکیده

BACKGROUND Bronchial artery (BA) embolization (BAE) is recommended as a minimally invasive therapy for hemoptysis, though some patients recover after only conservative treatment. OBJECTIVES The purpose of our study was to assess the characteristics of BAs using multidetector row computed tomography (MDCT) and identify BAs requiring BAE without BA angiography (BAG). METHODS We retrospectively studied 41 patients and classified the visualized BAs into groups based on their BAE and bleeding statuses. Patients presenting with massive hemoptysis requiring emergency BAE were excluded. Patients presenting with persistent hemoptysis that was resistant to conservative treatment received BAE. Radiologists measured BA diameters at the ostium, bronchial bifurcation and pulmonary hilum, and also evaluated the degree of vascularization. RESULTS MDCT enabled visualization of 102 ostia and 96 traceable BAs. Among the participating patients, 13 had at least one ectopic origin. We obtained a good correlation between BAG and MDCT diameters (r = 0.709, p < 0.001). The diameters of BAs responsible for bleeding and receiving BAE were apparently larger in each measured segment than those that were not (p < 0.05). Moreover, the diameters of arteries receiving BAE remained largely unchanged from the origin to the hilum and through the mediastinum. BAs with low MDCT scores were significantly less likely to required BAE than those with high scores (p = 0.004), and in multiple logistic regression analysis, ostium diameter and bleeding status were independent predictive factors for BAE. CONCLUSIONS Evaluation of BAs on MDCT could be useful for identifying the anatomical characteristics of bleeding-related BAs and determining whether BAE is indicated or whether conservative treatment is sufficient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Value of 320-Row Multidetector CT Bronchial Arteriography in Recurrent Hemoptysis after Failed Transcatheter Arterial Embolization.

PURPOSE To retrospectively assess the value of computed tomographic (CT) bronchial arteriography (BA) with 320-row multidetector CT in the management of patients with recurrent hemoptysis immediately after bronchial artery embolization (BAE). MATERIALS AND METHODS Among 135 consecutive patients treated with BAE between April 2014 and March 2016, recurrent hemoptysis developed in 15, and 10 su...

متن کامل

Multidetector CT of bronchial and non-bronchial systemic arteries.

We evaluate the use of multidetector row computed tomography (MDCT) angiography for the depiction of bronchial and non-bronchial systemic arteries (NBSAs), which frequently become enlarged as a secondary finding in a wide array of chronic lung diseases and other diseases that affect the pulmonary vascular system. MDCT angiography has enabled radiologists to provide thin-slice axial images, mult...

متن کامل

Bronchial Artery Embolization for Massive Hemoptysis: a Retrospective Study

  Introduction: To assess the efficacy and safety of bronchial artery embolization in the treatment of massive hemoptysis.   Materials and Methods: A retrospective study on 46 patients (26 males and 20 females) who were referred to the Razavi Hospital from April 2009 to May 2012 with massive hemoptysis and had bronchial artery embolization procedures. General characteristics of the patients inc...

متن کامل

THERAPEUTIC EMBOLIZATION OF BRONCHIAL ARTERY FOR MASSIVE HEMOPTYSIS

34 bronchial and 13 intercostal arteries were selectively embolized in 27 patients. The most frequent predisposing factor was either active or residual pulmonary tuberculosis. The procedure was performed with Urografin as the contrast agent, cobra shaped or headhunter catheters, and gelfoam (no. 18) or Ivalon (no. 9) particles. The most common anatomic pattern was a common bonchial artery ...

متن کامل

Volume-rendered hemorrhage-responsible arteriogram created by 64 multidetector-row CT during aortography: utility for catheterization in transcatheter arterial embolization for acute arterial bleeding

Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram crea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 2010