Incremental diagnostic value of preoperative 99mTc-MIBI SPECT in patients with a parathyroid adenoma.
نویسندگان
چکیده
UNLABELLED The purpose of this prospective study was to evaluate the diagnostic value of early parathyroid SPECT combined with quantitative analysis as compared with planar imaging in patients undergoing minimally invasive radioguided surgery. METHODS A total of 52 consecutive patients with primary hyperparathyroidism underwent planar and SPECT parathyroid scintigraphy 2-5 d before surgery. Each patient had a single-tracer dual-phase technique using (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) and a double-tracer subtraction technique using a delayed (99m)Tc-pertechnetate scan. Immediately after the first (99m)Tc-MIBI planar image, a SPECT study was acquired. Before radioguided parathyroidectomy, each patient was reinjected with (99m)Tc-MIBI. Serum calcium levels were available for all patents before surgery and at 8 and 24 h after surgery. Serum parathyroid hormone (PTH) levels were also available for all patients. Quantitative analysis was performed using the average count ratio of parathyroid to left thyroid lobe, right thyroid lobe, and maximum thyroid activity. All patients had histopathologic examination of the removed glands. RESULTS The average time for radioguided surgery was 30 min (range, 20-40 min). Postsurgical calcium levels correlated significantly with the adenoma weight (r = 0.5; P = 0.016). Combined planar scintigraphy correctly identified 41 adenomas (79%). SPECT increased the sensitivity to 96%. SPECT was superior to planar imaging in 9 patients, mainly in patients with ectopic adenomas or with multinodular goiters. Gland size did not affect significantly the detectability of SPECT. (99m)Tc-MIBI retention was noted in only 31 adenomas (60%). The average uptake ratios of parathyroid counts to the left lobe, right lobe, and maximum thyroid activity were 1.20 +/- 0.42, 1.29 +/- 0.45, and 0.84 +/- 0.35, respectively. The latter ratio was significantly correlated with PTH levels before surgery (r = 0.408; P = 0.04). CONCLUSION Our data indicate that early preoperative SPECT in patients with primary hyperparathyroidism is essential for accurate localization of parathyroid adenomas and for the selection of patients who are candidates for minimally invasive radioguided surgery. Planar parathyroid imaging is less sensitive compared with SPECT, and washout kinetics of (99m)Tc-MIBI are unreliable in the dual-phase technique. Patients with higher presurgical PTH levels may especially benefit from radioguided surgery.
منابع مشابه
Assessment of the integrated role of myocardium perfusion gated SPECT study in patient with parathyroid adenoma by 99mTc-sestamibi
Introduction: The purpose of this study is to assess the integrated role of scintigraphy by Tc99m MIBI in diagnosis of parathyroid adenoma and its impacts on the myocardium, and to evaluate whether myocardium perfusion gated SPECT study could be a complementary routine workup for patient with positive parathyroid adenoma on Tc99m MIBI parathyroid scan. Methods: Rest myocardium perfusion gated ...
متن کاملMultiple brown tumors in a patient with parathyroid adenoma depicting affinity for both 99mTc -pertechnetate and 99mTc-MIBI: Evaluation with hybrid SPECT/CT
Parathyroid adenoma involving a single parathyroid gland is the underlying cause of 80-85% of primary hyperparathyroidism (PHPT). Skeletal system is significantly affected by PHPT. Brown tumors are known to have affinity for 99mTc-MIBI. We report a rare case of PHPT presenting with diffuse bony pain, high calcium level and significantly elevated alkaline phosphatase level. 99m<...
متن کاملIs Brown Adipose Tissue Visualization Reliable on 99mTc-Methoxyisobutylisonitrile Diagnostic SPECT Scintigraphy?
The 99mTc-MIBI has been used with great value as a diagnostic technique in patients with primary hyperparathyroidism. False-positive scans may occur due to misinterpretation of the physiologic distribution of the 99mTc-MIBI. Reviewing consecutive SPECT scans, we evaluated this possibility and assessed how frequently brown adipose tissue (BAT) is seen on 99mTc-MIBI scintigraphy. Here, we retrosp...
متن کاملAtypical non-[99mTc]Tc-MIBI avid parathyroid adenoma with a sternal brown tumor, mimicking ectopic parathyroid adenoma in planar and SPECT images: Importance of SPECT/CT acquisition
Primary hyperparathyroidism (pHPT) is defined by the excess level of parathyroid hormone (PTH). Parathyroid adenoma is responsible for about 80% of all pHPT. Parathyroid adenoma with cystic feature and atypical pathology is recognized as a rare entity. Technetium-99m methoxy isobutyl isonitrile ([99mTc]Tc-MIBI) scintigraphy has favorable detection rate for ectopic gland as well as th...
متن کامل99mTc-MIBI SPECT/CT imaging contribution in the diagnosis of patients with hyperparathyroidism
Introduction: Hyperparathyroidism is presented with increased parathyroid hormone (PTH) secretion due to hyperfunctioning of one or more of the four parathyroid glands. Primary hyperparathyroidism (p-HPT) can be due to parathyroid adenoma, hyperplasia or carcinoma of the parathyroid gland. Secondary hyperparathyroidism (s-HPT) is usually a response to hypocalcaemia and consecut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 44 6 شماره
صفحات -
تاریخ انتشار 2003