AbstractID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT

ثبت نشده
چکیده

ID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT Purpose: To evaluate the potential for Co-60 based tomotherapy including dose delivery and mega-voltage CT (MVCT). Tomotherapy is a rotational implementation of IMRT that provides highly conformal doses and patient setup verification using MVCT. Current tomotherapy is limited to linear accelerators. This poster presents advances in our investigation of Cobalt-60 based tomotherapy, including MVCT. Method and Materials: The fundamental components for the Co-60 tomotherapy dose delivery and MVCT imaging experiments are a benchtop motion stage and a clinical Co-60 MDS Nordion T-780 unit. Film and polymer-gel dosimetry are used to validate the tomotherapy dose delivery planned using in-house software. Imaging is provided by a Varian Portal Vision LC250 EPID. MVCT imaging is demonstrated using a variety of phantoms, including an anthropomorphic head phantom, and various contrast phantoms. EGS Monte Carlo simulation is used to model different beam delivery approaches such as source design for increased radiation output. Results: The computer simulations, film dose measurements, and three-dimensional polymer gel dosimetry all demonstrate that Co-60 tomotherapy provides conformal dose delivery required of modern IMRT techniques. Film measurements show that dose delivery corresponds excellently with treatment plans, validating our in-house planning system. Treatment planning studies show that Co-60 tomotherapy delivery compares favourably with that from linac based 6MV tomotherapy. Dose volume histograms show identical coverage and avoidance of target critical organs. Imaging results show that Co-60 CT provides sufficient contrast and resolution for image guidance. Results from Monte Carlo studies show that it is possible to increase beam output for a dedicated Co60 tomotherapy unit by modifying the source geometry. Conclusion: Co-60 is well suited to tomotherapy and imaging applications; the development of clinical implementations of Co-60 tomotherapy is warranted and work continues in our centre along these lines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of optimal fiducial marker across image‐guided radiation therapy (IGRT) modalities: visibility and artifact analysis of gold, carbon, and polymer fiducial markers

The purpose of this study was to evaluate the visibility and artifact created by gold, carbon, and polymer fiducial markers in a simple phantom across computed tomography (CT), kilovoltage (kV), and megavoltage (MV) linear accelerator imaging and MV tomotherapy imaging. Three types of fiducial markers (gold, carbon, and polymer) were investigated for their visibility and artifacts in images acq...

متن کامل

Intensity Modulated Arc Therapy: Technology and Clinical Implementation

ID: 10351 Title: Advances in arc therapy Intensity Modulated Arc Therapy: Technology and Clinical Implementation Cedric X. Yu University of Maryland School of Medicine AbstractID: 10351 Title: Advances in arc therapyID: 10351 Title: Advances in arc therapy Abstract Intensity modulated arc therapy (IMAT) was proposed by Yu as an alternative to Tomotherapy. Over more than a decade, many progresse...

متن کامل

Tomotherapy as a tool in image-guided radiation therapy (IGRT): theoretical and technological aspects

Helical tomotherapy (HT) is a novel treatment approach that combines Intensity-Modulate Radiation Therapy (IMRT) delivery with in-built image guidance using megavoltage (MV) CT scanning. The technique utilises a 6 MV linear accelerator mounted on a CT type ring gantry. The beam is collimated to a fan beam, which is intensity modulated using a binary multileaf collimator (MLC). As the patient ad...

متن کامل

Current status of the infrastructure and characteristics of radiation oncology in Korea.

BACKGROUND An analysis of radiotherapy infrastructure in Korea was performed in 2006 to collect data on treatment devices, the work force and new patients for future development plans. METHODS The survey included radiotherapy centers, their major equipment and personnel. The centers were categorized into four levels: level 0 (stand-alone teletherapy units); level 1 (teletherapy, brachytherapy...

متن کامل

A planning study for palliative spine treatment using StatRT and megavoltage CT simulation†

Megavoltage CT (MVCT) simulation on the TomoTherapy Hi·Art system is an alternative to conventional CT for treatment planning in the presence of severe metal artifact. StatRT is a new feature that was implemented on the TomoTherapy operator station for performing online MVCT scanning, treatment planning and treatment delivery in one session. The clinical feasibility of using the StatRT techniqu...

متن کامل