FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations.

نویسندگان

  • R Kramer
  • V F Cassola
  • H J Khoury
  • J W Vieira
  • V J de Melo Lima
  • K Robson Brown
چکیده

Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been developed in the first part of this study using 3D animation software and anatomical atlases to replace the image-based FAX06 and the MAX06 voxel phantoms. 3D modelling methods allow for phantom development independent from medical images of patients, volunteers or cadavers. The second part of this study investigates the dosimetric implications for organ and tissue equivalent doses due to the anatomical differences between the new and the old phantoms. These differences are mainly caused by the supine position of human bodies during scanning in order to acquire digital images for voxel phantom development. Compared to an upright standing person, in image-based voxel phantoms organs are often coronally shifted towards the head and sometimes the sagittal diameter of the trunk is reduced by a gravitational change of the fat distribution. In addition, volumes of adipose and muscle tissue shielding internal organs are sometimes too small, because adaptation of organ volumes to ICRP-based organ masses often occurs at the expense of general soft tissues, such as adipose, muscle or unspecified soft tissue. These effects have dosimetric consequences, especially for partial body exposure, such as in x-ray diagnosis, but also for whole body external exposure and for internal exposure. Using the EGSnrc Monte Carlo code, internal and external exposure to photons and electrons has been simulated with both pairs of phantoms. The results show differences between organ and tissue equivalent doses for the upright standing FASH/MASH and the image-based supine FAX06/MAX06 phantoms of up to 80% for external exposure and up to 100% for internal exposure. Similar differences were found for external exposure between FASH/MASH and REGINA/REX, the reference voxel phantoms of the International Commission on Radiological Protection. Comparison of effective doses for external photon exposure showed good agreement between FASH/MASH and REGINA/REX, but large differences between FASH/MASH and the mesh-based RPI_AM and the RPI_AF phantoms, developed at the Rensselaer Polytechnic Institute (RPI).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of 5- and 10-year-old pediatric phantoms based on polygon mesh surfaces.

PURPOSE The purpose of this study is the development of reference pediatric phantoms for 5- and 10-year-old children to be used for the calculation of organ and tissue equivalent doses in radiation protection. METHODS The study proposes a method for developing anatomically highly sophisticated pediatric phantoms without using medical images. The 5- and 10-year-old male and female phantoms pre...

متن کامل

Development of Iranian Adult Female Reference Phantom for Internal Dosimetry Calculations

Estimation of organ doses in diagnostic and therapeutic nuclear medicine procedures is an area of particular concern for radiation protection, in all over the world. The stylized computational phantoms have contributed significantly to radiation dosimetry in nuclear medicine; however, their simplified treatment of human anatomy is being criticized. Due to the fact that the ICRP adult reference ...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Developing the Adult Male ICRP Phantom and Evaluation the Absorbed Dose Received By Critical Organs in Head and Neck Region during the Radiotherapy of Eye Cancer

Introduction Accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms. The International Commission on Radiological Protection (ICRP) reference phantoms can provide a more realistic view of the human anatomy in comparison with the previously used mathematical p...

متن کامل

CALDose_X online: Web-based, real time Monte Carlo calculations for patient dosimetry in X-ray diagnosis

CALDose_X 5.0 is a software package for the calculations of organ and tissue absorbed doses, as well as cancer risks for patients submitted to examinations of conventional radiography which can be downloaded from www.caldose.org. The program is based on conversion coefficients (CCs) between organ and tissue absorbed dose and measurable quantities, calculated with the MASH and FASH adult referen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 55 1  شماره 

صفحات  -

تاریخ انتشار 2010