A study of circulatory dynamics by means of crystal radiation detectors on the anterior thoracic wall.

نویسندگان

  • R L HUFF
  • D PARRISH
  • W CROCKETT
چکیده

A description is given of simultaneous tape records from four well-shielded crystal detectors placed on the anterior chest in the projections of the right atrium, pulmonary artery, ventricles, and lung vessels alone. Single intravenous injections of I human serum albumin were made. Cardiac outputs calculated from the observed data compare favorably with those obtained by catherization. Use of the tape recorder with slow playback speeds allows for unique storage, transformation and interpretation of data. Characteristic curves obtained from patients with congenital and valvular heart disease are analyzed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Anterior Cervical Incision and Thoracotomy for Cervico-thoracic, Thoracic, and Thoracolumbar Spine Surgery: A Clinical Series

Introduction:Surgical treatment of diseases in cervicothoracic, thoracic and thoracolumbar regions can be a challenging issue. Cooperation of the thoracic surgeons and spine surgeons can improve the outcomes and decrease the complications of patients who underwent these approaches.Materials & Methods: The participants of this study consisted of seventeenpatients suffering from different types o...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

The Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study

Introduction:  In  this  study,  we  utilized  the  MCNP4C  Monte  Carlo  code  to  quantitatively  evaluate  the  influence of crystal size and material on intercrystal scatter and parallax effects.   Materials and Methods:  For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of  511  keV  photons  originating  from  a  point  source  and  incident  on  the  central  cry...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 1957