Polyurethane foam (PUF) passive samplers for monitoring phenanthrene in stormwater.

نویسندگان

  • Yueqin Dou
  • Tian C Zhang
  • Jing Zeng
  • John Stansbury
  • Massoum Moussavi
  • Dana L Richter-Egger
  • Mitchell R Klein
چکیده

Pollution from highway stormwater runoff has been an increasing area of concern. Many structural Best Management Practices (BMPs) have been implemented for stormwater treatment and management. One challenge for these BMPs is to sample stormwater and monitor BMP performance. The main objective of this study was to evaluate the feasibility of using polyurethane foam (PUF) passive samplers (PSs) for sampling phenanthrene (PHE) in highway stormwater runoff and BMPs. Tests were conducted using batch reactors, glass-tube columns, and laboratory-scale BMPs (bioretention cells). Results indicate that sorption for PHE by PUF is mainly linearly relative to time, and the high sorption capacity allows the PUF passive sampler to monitor stormwater events for months or years. The PUF passive samplers could be embedded in BMPs for monitoring influent and effluent PHE concentrations. Models developed to link the results of batch and column tests proved to be useful for determining removal or sorption parameters and performance of the PUF-PSs. The predicted removal efficiencies of BMPs were close to the real values obtained from the control columns with errors ranging between -8.46 and 1.52%. This research showed that it is possible to use PUF passive samplers for sampling stormwater and monitoring the performance of stormwater BMPs, which warrants the field-scale feasibility studies in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outdoor passive air monitoring of semi volatile organic compounds (SVOCs): a critical evaluation of performance and limitations of polyurethane foam (PUF) disks.

The most commonly used passive air sampler (PAS) (i.e. polyurethane foam (PUF) disk) is cheap, versatile, and capable of accumulating compounds present both in gas and particle phases. Its performance for particle associated compounds is however disputable. In this study, twelve sets of triplicate PUF-PAS were deployed outdoors for exposure periods of 1-12 weeks together with continuously opera...

متن کامل

Effect based monitoring of seasonal ambient air exposures in Australia sampled by PUF passive air samplers.

There has been relatively little bioanalytical effect based monitoring conducted using samples derived from polyurethane foam (PUF) passive air samplers. Combining these techniques may provide a more convenient and cost effective means of monitoring the potential for biological effects resulting from exposure to complex mixtures in a range of scenarios. Seasonal polycyclic aromatic hydrocarbon ...

متن کامل

An application of passive samplers to understand atmospheric mercury concentration and dry deposition spatial distributions.

Two modified passive samplers were evaluated at multiple field locations. The sampling rate (SR) of the modified polyurethane foam (PUF)-disk passive sampler for total gaseous mercury (TGM) using gold-coated quartz fiber filters (GcQFF) and gaseous oxidized mercury (GOM) using ion-exchange membranes (IEM) were 6.4 ± 1.4 and 15.3 ± 0.3 m(3) day(-1), respectively. The relative percent difference ...

متن کامل

SAMPLING, CLEAN-UP AND SEPARATION Evaluation of performance reference compounds in PUF passive air samplers at different wind speeds

ORGANOHALOGEN COMPOUNDS – Volume 66 (2004) 138 Introduction Polyurethane foam (PUF) samplers are being used in an increasing number of studies to passively sample semivolatile organic compounds (SOCs) in the atmosphere (e.g. 1, ). However, recent research shows that the uptake and loss kinetics of passive air samplers is influenced by changes in wind speed . According to theory, the rate of che...

متن کامل

Sampling medium side resistance to uptake of semivolatile organic compounds in passive air samplers.

Current theory of the uptake of semivolatile organic compounds in passive air samplers (PAS) assumes uniform chemical distribution and no kinetic resistance within the passive sampling media (PSM) such as polystyrene-divinylbenzene resin (XAD) and polyurethane foam (PUF). However, these assumptions have not been tested experimentally and are challenged by some recently reported observations. To...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science. Processes & impacts

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 2016