Use of a Combined SpO2/PtcCO2 Sensor in the Delivery Room

نویسندگان

  • Serena Antonia Rubortone
  • Maria Pia De Carolis
  • Serafina Lacerenza
  • Iliana Bersani
  • Federica Occhipinti
  • Costantino Romagnoli
چکیده

Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recently used in neonatal clinical practice (TOSCA(500Ò)Radiometer). We evaluated TOSCA usability and reliability in the delivery room (DR), throughout three different periods, on term, late-preterm, and preterm neonates. During the first period (period A), 30 healthy term neonates were simultaneously monitored with both TOSCA and a MASIMO pulse oximeter. During the second period (period B), 10 healthy late-preterm neonates were monitored with both TOSCA and a transcutaneous device measuring PtcCO(2) (TINA(Ò) TCM3, Radiometer). During the third period (period C), 15 preterm neonates were monitored with TOSCA and MASIMO after birth, during stabilization, and during transport to the neonatal intensive care unit (NICU). Blood gas analyses were performed to compare transcutaneous and blood gas values. TOSCA resulted easily and safely usable in the DR, allowing reliable noninvasive SaO(2) estimation. Since PtcCO(2) measurements with TOSCA required at least 10 min to be stable and reliable, this parameter was not useful during the early resuscitation immediately after birth. Moreover, PtcCO(2) levels were less precise if compared to the conventional transcutaneous monitoring. However, PtcCO(2) measurement by TOSCA was useful as trend-monitoring after stabilization and during transport to NICU.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The survey of Rrespiratory Rate, SPO2, nausea and vomiting in the use of three methods (warmed intravenous fluids, combined warming and pethidine) in patients with shivering

Introduction: Shivering after anaesthesia and surgery is a common complication. Different methods are used for control of shivering in the recovery room. The opioids such as pethidine are very common in shivering control. Pethidine can be induced apnea, respiratory depression and nausea &vomiting. The respiratory rate and spo2 can lead to more rapid diagnosis and treatment of serious hypoxemia ...

متن کامل

Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea.

OBJECTIVES The purpose of the study was to evaluate a novel, combined sensor for transcutaneous monitoring of arterial oxygen saturation and carbon dioxide tension. DESIGN The new monitoring technique was compared to established reference methods. SETTING ICU and sleep laboratory of a university hospital. PATIENTS Eighteen critically ill adult patients with acute respiratory failure or he...

متن کامل

Oxygen saturation in healthy infants immediately after birth.

OBJECTIVE Because the optimal concentration of oxygen (FiO2) required for stabilization of the newly born infant has not been established, the FiO2 is commonly adjusted according to the infant's oxygen saturation (SpO2). We aimed to determine the range of pre-ductal SpO2 in the first minutes of life in healthy newborn infants. STUDY DESIGN We applied an oximetry sensor to the infant's right p...

متن کامل

Home monitoring of daytime mouthpiece ventilation effectiveness in patients with neuromuscular disease.

Mouthpiece ventilation (MPV) allows patients with neuromuscular disease to receive daytime support from a portable ventilator, which they can disconnect at will, for example, for speaking, eating, swallowing, and coughing. However, MPV carries a risk of underventilation. Our purpose here was to evaluate the effectiveness of daytime MPV under real-life conditions. Eight wheelchair-bound patients...

متن کامل

Effect of Nail Polish on Pulse Oximetry Findings in Healthy Volunteers: A Randomized Clinical Trail

Background and Objectives: Pulse oximetry is the most common technique for monitoring hemoglobin oxygen saturation (SpO2). Different colors and brands of nail polish may cause disturbance in the reading and interpretation of oxygen saturation. The aim of this study was to determine the effect of different colors of nail polish on oxygen saturation measured by pulse oximeter. Methods: Thirty he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012