Capacitive Micromachined Ultrasonic Transducer Technology for Medical Ultrasound Imaging
نویسندگان
چکیده
Capacitive micromachined ultrasonic transducer (cMUT) technology has been recognized as an attractive alternative to the more traditional piezoelectric transducer technology in medical ultrasound imaging for several years now. There are mainly two reasons for the interest in this technology: Micromachining is derived from the integrated circuit technology and therefore shares the well-known advantages and experience of it. Also, capacitive transduction using thin membranes has fundamental superiorities over the piezoelectric transduction mechanism such as wide frequency bandwidth. Capacitive micromachined ultrasonic transducers are essentially capacitor cells where the two plates of the capacitor, the membrane and the substrate, are separated with a vacuum sealed cavity. Typically, a cMUT is made of many microscale capacitor cells operating in parallel. This paper describes a new fabrication technique for building cMUTs which is called the wafer-bonding method. In this method, the cavity and the membrane are defined on separate wafers and brought together by wafer-bonding in vacuum. The wafer-bonding method has several advantages over the traditional sacrificial release method of cMUT fabrication. It allows greater flexibility in the cMUT design which means better device performance. It reduces the number of process steps, device turn-around time, and increases the overall uniformity, reliability. and repeatability. Device examples of one-dimensional and two-dimensional arrays designed to work in the 1 to 50 MHz range with 100 % fractional bandwidth highlight the advantages of this method, and show that cMUT technology is indeed the better candidate for next generation ultrasonic imaging arrays.
منابع مشابه
Micromachined Capacitive Ultrasonic Immersion Transducer for Medical Imaging
Piezoceramics have been the dominant transducer technology in ultrasound medical imaging for several decades. Recent progress in surface micromachined capacitive ultrasonic immersion transducers makes them an alternative transducer technology, especially in highly integrated twodimensional arrays. This paper demonstrates that the surface micromachined capacitive ultrasonic immersion transducer ...
متن کاملCapacitive micromachined ultrasonic transducer (CMUT) arrays for medical imaging
Capacitive micromachined ultrasonic transducers (CMUTs) bring the fabrication technology of standard integrated circuits into the field of ultrasound medical imaging. This unique property, combined with the inherent advantages of CMUTs in terms of increased bandwidth and suitability for new imaging modalities and high frequency applications, have indicated these devices as new generation arrays...
متن کاملCapacitive Micromachined Ultrasonic Transducers (CMUTs) for Underwater Imaging Applications
A capacitive micromachined ultrasonic transducer structure for use in underwater imaging is designed, fabricated and tested in this paper. In this structure, a silicon dioxide insulation layer is inserted between the top electrodes and the vibration membrane to prevent ohmic contact. The capacitance-voltage (C-V) characteristic curve shows that the transducer offers suitable levels of hysteresi...
متن کاملMedical imaging using capacitive micromachined ultrasonic transducer arrays.
We are investigating the use of capacitive micromachined ultrasonic transducers (cMUT's) for use in medical imaging. We propose an ultrasound probe architecture designed to provide volumetric ultrasound imaging from within an endoscope channel. A complete automated experimental system has been implemented for testing the imaging performance of cMUT arrays. This PC-based system includes custom-d...
متن کاملA 30-V transmitter front-end IC for ultrasound medical imaging applications
A transmitter front-end IC for ultrasound medical imaging applications is implemented using 30-V 0.18-mm Bipolar/CMOS/DMOS process. The proposed ultrasound transmitter front-end, consisting of voltage level-shifters and an output driver, achieves high integration and maintains good reliability while generating a 33 ns output pulse signal in order to drive a large capacitive load, which represen...
متن کامل