Pacemaker or defibrillator surgery without interruption of anticoagulation.
نویسندگان
چکیده
BACKGROUND Many patients requiring pacemaker or implantable cardioverter-defibrillator (ICD) surgery are taking warfarin. For patients at high risk for thromboembolic events, guidelines recommend bridging therapy with heparin; however, case series suggest that it may be safe to perform surgery without interrupting warfarin treatment. There have been few results from clinical trials to support the safety and efficacy of this approach. METHODS We randomly assigned patients with an annual risk of thromboembolic events of 5% or more to continued warfarin treatment or to bridging therapy with heparin. The primary outcome was clinically significant device-pocket hematoma, which was defined as device-pocket hematoma that necessitated prolonged hospitalization, interruption of anticoagulation therapy, or further surgery (e.g., hematoma evacuation). RESULTS The data and safety monitoring board recommended termination of the trial after the second prespecified interim analysis. Clinically significant device-pocket hematoma occurred in 12 of 343 patients (3.5%) in the continued-warfarin group, as compared with 54 of 338 (16.0%) in the heparin-bridging group (relative risk, 0.19; 95% confidence interval, 0.10 to 0.36; P<0.001). Major surgical and thromboembolic complications were rare and did not differ significantly between the study groups. They included one episode of cardiac tamponade and one myocardial infarction in the heparin-bridging group and one stroke and one transient ischemic attack in the continued-warfarin group. CONCLUSIONS As compared with bridging therapy with heparin, a strategy of continued warfarin treatment at the time of pacemaker or ICD surgery markedly reduced the incidence of clinically significant device-pocket hematoma. (Funded by the Canadian Institutes of Health Research and the Ministry of Health and Long-Term Care of Ontario; BRUISE CONTROL ClinicalTrials.gov number, NCT00800137.).
منابع مشابه
Perioperative anticoagulation in patients having implantation of a cardiac pacemaker or defibrillator: a systematic review and practical management guide.
BACKGROUND The perioperative management of anticoagulation in patients who are having implantation of a pacemaker or implantable cardioverter defibrillator (ICD) is a common clinical problem in which best clinical practise is not established. METHODS We performed a systematic review of the literature to assess the safety (pocket hematoma risk) and efficacy (thromboembolism risk) of different ...
متن کاملManagement of anticoagulation around pacemaker and defibrillator surgery.
ach year, an estimated 1.25 million pacemakers and 410 000 implantable cardioverter-defibrillators are implanted worldwide. 1 Clinical trials suggest that ≈25% of pacemaker and 35% of implantable cardioverter-defibrillator patients receive long-term oral anticoagulation (OAC). The periprocedural management of their OAC presents a dilemma. This is particularly true in the subset of patients with...
متن کاملSafety and efficacy of bridging with low molecular weight heparins: a systematic review and partial meta-analysis.
BACKGROUND Surgical interventions in patients on long term vitamin K antagonist (VKA) treatment create a dilemma; periprocedural interruption of anticoagulation raises the risk of thrombosis, while continuation raises the risk of bleeding. The anticoagulation- free interval is minimized by "bridging" with parenteral anticoagulants. The efficacy and safety of bridging with low molecular weight h...
متن کاملComparison of the effect of training by video and group discussion on the level of stress, anxiety, depression and self-efficacy of patients undergoing pacemaker and cardiac implantation defibrillator
متن کامل
Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The New England journal of medicine
دوره 368 22 شماره
صفحات -
تاریخ انتشار 2013