The effects of short-term venous congestion on forearm venous volume and reactive hyperemia blood flow in human subjects.

نویسندگان

  • R Zelis
  • R Capone
  • E Mansour
  • J M Field
چکیده

Congestive heart failure is associated with a reduction in limb venous volume at an effective venous pressure of 30 mm Hg (VV[30]). Further, an attenuated arteriolar dilation in response to a metabolic stimulus has been demonstrated. It was the purpose of this study to determine to what extent the chronic elevation in venous pressure seen in heart failure might explain these abnormalities of the limb circulation. Ten normal human volunteers were subjected to venous congestion of one arm for three hours at 70 mm Hg. A mercury-in-rubber strain gauge plethysmograph was used to measure forearm VV [30] and forearm blood flow at rest after release of five minutes of arterial occlusion (the reactive hyperemia response). Congestion reduced VV [30] 22%, resting forearm blood flow 49% and peak reactive hyperemia blood flow 25%. Thus, chronic venous congestion per se may significantly reduce limb venous volume as well as resting and reactive hyperemia blood flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تأثیر Vacuum-Compression Therapy (VCT) بر جریان خون اندام دیابتی

Background: Chronic diabetes is substantially associated with circulatory disorders in lower limbs. Vacuum-Compression Therapy (VCT) has been commonly used in treatment of peripheral circulatory disorders. VCT is based on intermittent alteration of Positive- Negative pressure phases. The purpose of this study was to determine effects of VCT on diabetic subjects' peripheral blood flow.Methods: I...

متن کامل

Radionuclide plethysmography for noninvasive evaluation of peripheral arterial blood flow.

We validated a noninvasive radionuclide plethysmography technique to evaluate peripheral arterial blood flow during reactive hyperemia. This method, based on the measurement of blood volume variations during repetitive venous occlusions, was compared with strain-gauge venous impedance plethysmography. The technique uses 99mTc-labeled autologous red blood cells scintigraphy to determine the rate...

متن کامل

Effect of Inhaled Carbon Ultrafine Particles on Reactive Hyperemia in Healthy Human Subjects

BACKGROUND Ultrafine particles (UFP) may contribute to the cardiovascular effects of exposure to particulate air pollution, partly because of their relatively efficient alveolar deposition and potential to enter the pulmonary vascular space. OBJECTIVES This study tested the hypothesis that inhalation of elemental carbon UFP alters systemic vascular function. METHODS Sixteen healthy subjects...

متن کامل

Reproducibility of blood flow and post-occlusive reactive hyperaemia as measured by venous occlusion plethysmography.

Venous occlusion plethysmography is commonly used as a tool to assess BF (blood flow) and VR (vascular resistance) at baseline and during PORH (post-occlusive reactive hyperaemia). However, little is known about the reproducibility of this method. The purpose of the present study was to investigate short- (hours) and medium (week)-term reproducibility of forearm, calf and thigh BF and VR at bas...

متن کامل

Inhibition of vascular ATP-sensitive K+ channels does not affect reactive hyperemia in human forearm.

The extent to which ATP-sensitive K(+) channels contribute to reactive hyperemia in humans is unresolved. We examined the role of ATP-sensitive K(+) channels in regulating reactive hyperemia induced by 5 min of forearm ischemia. Thirty-one healthy subjects had forearm blood flow measured with venous occlusion plethysmography. Reactive hyperemia could be reproducibly induced (n = 9). The contrib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 1978