AN IMPROVED AEROSOL GENERATION SYSTEM FOR THE PREPARATION OF XRF CALIBRATION FILTERS, C. Vanhoof, V. Corthouts and N. De Brucker, pp. 449-455
نویسندگان
چکیده
A fast and reliable method for the analysis of airborne loaded filters becomes more and more important for monitoring campaigns and inventory studies at sites with airborne pollution. Xray fluorescence spectroscopy (XRF) can perform quantitative analysis on filters without any pretreatment. Quantitative determination of various metals on loaded filters requires the use of calibration curves set up with synthetic filters. For accurate analysis, the calibration standards have to be prepared with a comparable matrix composition as the real filter samples. Therefore, cellulose nitrate filters were loaded by means of aerosol generation with various metals. The performance of an optimized aerosol generation system, based on the ultrasonic nebulization of a multi-element solution, is presented in this work. A multi-element solution is converted into a fine dense aerosol by ultrasonic action. The produced aerosol is dried and collected onto a filter. Filters can be loaded sequentially with a maximum standard deviation of 5 % for various metal concentrations. The influence of loading time and alteration of the initial metal concentration on the obtained elemental concentration have been investigated. Finally, the validation of the XRF measurement method is described. The linearity and sensitivity of the calibration curves are calculated for the various metals. The XRF detection limits, repeatability, and accuracy are determined. The XRF analysis of real filter samples is confirmed by subsequent analysis of filter samples with ICP-OES after acid digestion.
منابع مشابه
ارزیابی پارامترهای عملکردی در فیلترهای هپا در یک صنعت دارویی(مطالعه موردی1394)
Abstract: Background and aims: Nowadays, cleanrooms have become impartible parts of an industry with sensitive products. Sources of contamination in cleanrooms are impaired performance and quality sensitive products in the cleanrooms .The aim of this study was to evaluate the efficiency of HEPA filter and check the concentration and number of airborne particles in cleanrooms for pharmaceutic...
متن کاملQUANTIFICATION OF GALLIUM IN DRIED RESIDUE SAMPLES BY XRF: AN IMPROVED SAMPLE PREPARATION METHOD FOR ANALYZING PLUTONIUM METAL, C.G. Worley, pp. 421-426
A novel XRF sample preparation method was investigated to quantify the concentration of gallium in plutonium metal and minimize the possibility of contaminating the instrument with radioactive material. To prepare homogenous specimens and to add an internal standard, the plutonium must first be dissolved. The currently established method then entails removing the plutonium by chromatography and...
متن کاملPreparation and in-vitro characterization of alginate microspheres incorporating leptospiral antigens as a delivery system and adjuvant
Leptospirosis is one of the most prevalent zoonotic diseases worldwide. Currently, multivalent whole-cell leptospiral vaccines can induce protection against leptospirosis. Therefore, preparation and formulation of new generations of vaccines that can stimulate long-term immunity for leptospirosis control are essential. The aim of this study was to prepare and characterize alginate microspheres ...
متن کاملPreparation and Characterization of Modifed PEEK-WC: DEHPA Microspheres for Rhodamine B Adsorption. Kinetics Studies
Functionalized polymeric microspheres based on a modifed polyether ether keetone (PEEK-WC) using immersion precipitation techniques were successfully prepared by doping initial polymeric solutions with DEHPA. The viscosity of the doping solution was measured for determining the optimal value for obtaining reproducible capsules. The modifed microspheres were characterize...
متن کاملACCURATE QUANTIFICATION OF DRIED RESIDUE THIN FILMS USING X-RAY FLUORESCENCE, C.G. Worley, G.J. Havrilla, pp. 392-397
An XRF specimen preparation method was developed to quantify the concentration of gallium in plutonium metal while minimizing the risk of contaminating the instrument with radioactive material. To ensure that homogenous specimens are examined, plutonium is dissolved in dilute HCl and HNOJ prior to analysis. In the preliminary work here, non-radioactive aqueous gallium standards were prepared, a...
متن کامل