Autoregulation of cardiac output by passive elastic characteristics of the vascular capacitance system.

نویسندگان

  • C F Rothe
  • M L Gaddis
چکیده

After a change in cardiac output, the magnitude of potential blood volume redistribution was investigated in 10 dogs anesthetized with chloralose. All of the venous return was pumped into a reservoir, using servocontrolled pumps to maintain fixed superior and inferior vena cava pressures. The cardiac output was set at various levels by pumping from the reservoir into the right atrium. Changes in reservoir volume were assumed to reflect the changes in vascular blood volume. After measuring the control responses, cardiovascular reflexes were blocked with hexamethonium. Reducing the cardiac output, for example, from 110 to 80 ml/(min.kg) with reflexes intact, caused a 9.2-ml/kg transfer of blood from the dog to the reservoir. With reflexes blocked, the same change in cardiac output caused 6.8 ml/kg of the blood to be transferred. Under the control conditions, throughout the range of 50-140 ml/(min.kg), an increase or decrease of cardiac output of 1 ml/(min.kg) elicited a 0.304 +/- 0.086 (mean +/- SD) ml/kg change in dog blood volume; with reflexes blocked, the flow sensitivity was 0.239 +/- 0.062 ml/kg. Thus, only 21% of the total blood volume redistribution was attributable to active reflex responses. Deterioration of the preparation may have attenuated the magnitude of active reflex activity. Neither the systemic vascular compliance of 1.80 +/- 0.35 ml/mm Hg.kg nor the fraction of venous return from the superior vena cava of 26.5 +/- 4.6% was significantly changed by reflex blockade.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency response characteristics of whole body autoregulation of blood flow in rats.

Previously, we demonstrated that very low-frequency (VLF) blood pressure variability (BPV) depends on voltage-gated L-type Ca(2+)-channels, suggesting that autoregulation of blood flow and/or myogenic vascular function significantly contributes to VLF BPV. To further substantiate this possibility, we tested the hypothesis that the frequency response characteristic of whole body autoregulation o...

متن کامل

Erratum to: Volume and its relationship to cardiac output and venous return

Volume infusions are one of the commonest clinical interventions in critically ill patients yet the relationship of volume to cardiac output is not well understood. Blood volume has a stressed and unstressed component but only the stressed component determines flow. It is usually about 30 % of total volume. Stressed volume is relatively constant under steady state conditions. It creates an elas...

متن کامل

Simulation study of autoregulation responses of peripheral circulation to systemic pulsatility

BACKGROUND This simulation study investigated potential modulations of total peripheral resistance (TPR), due to distributed peripheral vascular activity, by means of a lumped model of the arterial tree and a non linear model of microcirculation, inclusive of local controls of blood flow and tissue-capillary fluid exchange. RESULTS Numerical simulations of circulation were carried out to comp...

متن کامل

A closed circulatory system model.

The model to be described is a “closed” system, comprised of four principal components : a pump, an arterial capacitance, a peripheral resistance, and a venous capacitance. The pump is servo-controlled, such that “cardiac output” is a function of venous pressure (FrankStarling mechanism). Also, because the model is a closed system, the venous pressure is a function of the cardiac output. The mo...

متن کامل

Design and Construction of a Sensitive Capasitive Sensor System (RESEARCH NOTE)

Design and construction of a capacitor sensor with a precise readout system are described in this paper. A variable air-gap capacitive transducer was constructed and for signalmeasurement a successful attempt was made to exploit the capacitance changes in terms of the phase angle of the detected signal. The reported setup makes it possible to detect capacitance changes of the order of 2.5 fF in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 1990