Velocity profiles in the main pulmonary artery of dogs and man, measured with a thin-film resistance anemometer.

نویسندگان

  • S R Reuben
  • J P Swadling
  • G J de Lee
چکیده

Instantaneous velocity of pulmonary artery blood was measured using a thin-film resistance anemometer mounted on a hypodermic needle. Studies were performed, at thoracotomy, in five dogs and five patients. Instantaneous blood velocity was recorded at several sites across die transverse axis of the main pulmonary artery to determine the shape of the velocity profile. We found the velocity profile, in both man and dog, to be approximately flat. In dog, the mean velocity, normalized to that at the center line, ranged from 1.18 (S D ± 0. 0 3) to 0.81 (S D ± 0. 2 7). In man, mean velocity of pulmonary artery blood, normalized in a similar fashion, ranged from 1.08 (SD ± 0.03) to 0.84 (S D ± 0.07), while the normalized peak systolic velocity ranged from 1.04 (S D ± 0. 0 7) to 0.95 (S D ± 0. 1 6). The results, in dogs, suggest that there is little asymmetry of the velocity profile and therefore these have been taken as evidence that the use of cuff electromagnetic flowmeters on the pulmonary artery of dogs is not subject to significant inaccuracies associated with a nonsymmetrical flow profile. The finding of a relatively flat velocity profile in patients, moreover, will make it easier for catheter-tip flowmeters to measure bulk velocity in the pulmonary artery. ADDITIONAL KEY WORDS axi-symmetrical Fourier analysis electromagnetic impedance pulmonary hypertension • Recently Schultz and his colleagues (1) described a thin-film resistance anemometer designed to measure instantaneous fluid velocity. The thin-film bead, when mounted on a hypodermic needle, was used by these workers to map the distribution of blood velocity across the transverse axis of the aorta in both dogs and man. They subsequently extended their work by measuring the velocity of aortic blood flow with a catheter-tip, thin-film resistance anemometer during routine cardiac catheterization. The results of this work have been reported in greater detail by Tunstall Pedoe (2). Several groups of workers have stressed the need for caution in the interpretation of flow measurements using cuff electromagnetic flowmeters. Wyatt (3), Goldman (4) and Bergel and Gessner (5) have particularly emphasized the need for the blood flow in a vessel to have an axi-symmetrical velocity profile, before the volume flow rate in that vessel can be related to the output of the electromagnetic flowmeter. However, at present the shape of the velocity profile in the pulmonary artery is not known. This knowledge …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs

Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...

متن کامل

Application of heated-film velocity and shear probes to hemodynamic studies.

A constant-temperature heated-film anemometer system has been adapted for the detailed study of in-vivo aortic velocity fields. Two types of sensing probes were developed: a velocity probe and a velocity-gradient or fluid shear stress probe. These probes were evaluated for steady and pulsatile flow in rigid circular tubes using both a glycerin-water mixture and blood. Measurements using both de...

متن کامل

Hot-Film Anemometer Velocity Measurements of Arterial Blood Flow in Horses

Blood velocity measurements were carried out using a constant-temperature hot-film anemometer system in both anesthetized and conscious horses. Catheter probes were used to measure velocity wave forms in conscious horses and L-shaped needle probes inserted by direct vessel puncture were used to measure the profiles in regions of the thoracic and abdominal aorta of anesthetized, open-chest horse...

متن کامل

Hot-film anemometer velocity measurements of arterial blood flow horses.

Blood velocity measurements were carried out using a constant-temperature hot-film anemometer system in both anesthetized and conscious horses. Catheter probes were used to measure velocity wave forms in conscious horses and L-shaped needle probes inserted by direct vessel puncture were used to measure the profiles in regions of the thoracic and abdominal aorta of anesthetized, open-chest horse...

متن کامل

Efficacy of High Dose Vitamin D on Pulmonary Artery Pressure in Thalassemia Patients Undergoing Blood Transfusion: A Randomized Trial

Background: Pulmonary arterial hypertension (PAH) may result in cardiomyopathy which is a major cause of death in thalassemia patients. Vitamin D is associated with benefits in cardiovascular disorders. Our purpose was to study effects of vitamin D on pulmonary artery pressure in thalassemia major and intermedia patients. Materials and Methods: This randomized trial was performed on 26 patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 1970