A randomized, double-masked, multicenter comparison of the safety of continuous intrathecal labor analgesia using a 28-gauge catheter versus continuous epidural labor analgesia.

نویسندگان

  • Valerie A Arkoosh
  • Craig M Palmer
  • Esther M Yun
  • Shiv K Sharma
  • James N Bates
  • Richard N Wissler
  • Jodie L Buxbaum
  • Wallace M Nogami
  • Edward J Gracely
چکیده

BACKGROUND Continuous intrathecal labor analgesia produces rapid analgesia or anesthesia and allows substantial flexibility in medication choice. The US Food and Drug Administration, in 1992, removed intrathecal microcatheters (27-32 gauge) from clinical use after reports of neurologic injury in nonobstetric patients. This study examined the safety and efficacy of a 28-gauge intrathecal catheter for labor analgesia in a prospective, randomized, multicenter trial. METHODS Laboring patients were randomly assigned to continuous intrathecal analgesia with a 28-gauge catheter (n = 329) or continuous epidural analgesia with a 20-gauge catheter (n = 100), using bupivacaine and sufentanil. The primary outcome was the incidence of neurologic complications, as determined by masked neurologic examinations at 24 and 48 h postpartum, plus telephone follow-up at 7-10 and 30 days after delivery. The secondary outcomes included adequacy of labor analgesia, maternal satisfaction, and neonatal status. RESULTS No patient had a permanent neurologic change. The continuous intrathecal analgesia patients had better early analgesia, less motor blockade, more pruritus, and higher maternal satisfaction with pain relief at 24 h postpartum. The intrathecal catheter was significantly more difficult to remove. There were no significant differences between the two groups in neonatal status, post-dural puncture headache, hemodynamic stability, or obstetric outcomes. CONCLUSIONS Providing intrathecal labor analgesia with sufentanil and bupivacaine via a 28-gauge catheter has an incidence of neurologic complication less than 1%, and produces better initial pain relief and higher maternal satisfaction, but is associated with more technical difficulties and catheter failures compared with epidural analgesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Epidural versus Entonox for Labor Analgesia in Nulliparous Women

 Introduction: The aim of this study is to compare the efficacy of epidural versus entonox methods for labor analgesia in nulliparous women.  Methods: This randomized controlled trial was performed on 84 nulliparous women with - pregnancy admitted to Imam Reza Hospital in 10 May 2010- 10 May 2011.  They were randomly divided into two groups 42 women inhaled entonox in active phase at the ...

متن کامل

Labor analgesia.

Regional analgesia has become the most common method of pain relief used during labor in the United States. Epidural and spinal analgesia are two types of regional analgesia. With epidural analgesia, an indwelling catheter is directed into the epidural space, and the patient receives a continuous infusion or multiple injections of local anesthetic. Spinal injections are usually single injection...

متن کامل

Intrathecal Analgesia Versus Non-analgesia in Labor on Maternal and Neonatal Outcomes

Aims: Spinal analgesia is the most common method that provides pain relief during labor and controversy exists about its effect on the maternal and fetal among the women. This study was conducted to determine the effect of intrathecal analgesia (ITA) on perineal laceration, duration of the first, second, and third stage of labor, and Apgar score. Materials & Methods: Fifty primipara parturien...

متن کامل

Patient-controlled epidural analgesia for labor.

Patient-controlled epidural analgesia (PCEA) for labor was introduced into clinical practice 20 yr ago. The PCEA technique has been shown to have significant benefits when compared with continuous epidural infusion. We conducted a systematic review using MEDLINE and EMBASE (1988-April 1, 2008) of all randomized, controlled trials in parturients who received PCEA in labor in which one of the fol...

متن کامل

A prospective controlled study of continuous spinal analgesia versus repeat epidural analgesia after accidental dural puncture in labour.

BACKGROUND After accidental dural puncture in labour it is suggested that inserting an intrathecal catheter and converting to spinal analgesia reduces postdural puncture headache and epidural blood patch rates. This treatment has never been tested in a controlled manner. METHODS Thirty-four hospitals were randomised to one of two protocols for managing accidental dural puncture during attempt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 108 2  شماره 

صفحات  -

تاریخ انتشار 2008