Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation.

نویسنده

  • M E Bastin
چکیده

Geometric distortions of echo-planar images produced by the strong eddy currents present in the diffusion tensor imaging experiment are a major confound to the accurate quantification of diffusion coefficients, and measures of diffusion anisotropy based upon them. Here we investigate how the method of iterative cross-correlation (ICC) of baseline and diffusion-weighted images (DWIs) originally proposed by Haselgrove and Moore (Magn. Reson. Med. 36:960-964; 1996) can be extended to correct high b-value DWIs, without the need for extrapolation of distortion parameters determined from low b-value images. Monte Carlo simulations of synthetic brain images show that the maximum value of the trace of the b-matrix, Tr(b), at which distorted DWIs can be accurately corrected by direct comparison with the undistorted baseline image is approximately 300 s mm(-2). Removal of the cerebrospinal fluid signal greatly extends this value of Tr(b) (up to approximately 2000 s mm(-2)), thereby allowing direct comparison of baseline and distorted images. The use of ICC distortion parameters determined from separate calibrations of water phantom images is also investigated, and found to be effective in correcting geometric distortions observed in the DWIs collected as part of a human volunteer diffusion tensor imaging study. This work suggests that distorted DWIs acquired at high values of b may be corrected using the ICC algorithm without collecting additional low b-value images, thus allowing simplified methods of measuring the apparent diffusion tensor D, based on collecting a small number of DWIs, to be implemented in quantitative patient examinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective Correction of Physiological Noise in DTI Using an Extended Tensor Model and Peripheral Measurements

Diffusion tensor imaging is widely used in research and clinical applications, but this modality is highly sensitive to artefacts. We developed an easy-to-implement extension of the original diffusion tensor model to account for physiological noise in diffusion tensor imaging using measures of peripheral physiology (pulse and respiration), the so-called extended tensor model. Within the framewo...

متن کامل

Eddy-Current Distortion Correction and Robust Tensor Estimation for MR Diffusion Imaging

This paper presents a new procedure to estimate the diffusion tensor from a sequence of diffusion-weighted images. The first step of this procedure consists of the correction of the distortions usually induced by eddy-current related to the large diffusion-sensitizing gradients. This correction algorithm relies on the maximization of mutual information to estimate the three parameters of a geom...

متن کامل

The impact of post-processing on spinal cord diffusion tensor imaging

Diffusion tensor imaging (DTI) provides information about the microstructure in the brain and spinal cord. While new neuroimaging techniques have significantly advanced the accuracy and sensitivity of DTI of the brain, the quality of spinal cord DTI data has improved less. This is in part due to the small size of the spinal cord (ca. 1cm diameter) and more severe instrumental (e.g. eddy current...

متن کامل

Correction for Eddy Current-Induced Echo-Shifting Effect in Partial-Fourier Diffusion Tensor Imaging

In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types...

متن کامل

An assessment of eddy current sensitivity and correction in single-shot diffusion-weighted imaging.

Artefacts caused by eddy currents are a major problem in diffusion weighted imaging. This is particularly acute in experiments in which a number of images with differing degrees of diffusion weighting and/or differently oriented diffusion-weighting gradients need to be combined. The echo-planar imaging sequence is particularly sensitive to the effects of residual eddy currents, especially due t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 1999