Sonication of removed hip and knee prostheses for diagnosis of infection.

نویسندگان

  • Andrej Trampuz
  • Kerryl E Piper
  • Melissa J Jacobson
  • Arlen D Hanssen
  • Krishnan K Unni
  • Douglas R Osmon
  • Jayawant N Mandrekar
  • Franklin R Cockerill
  • James M Steckelberg
  • James F Greenleaf
  • Robin Patel
چکیده

BACKGROUND Culturing of samples of periprosthetic tissue is the standard method used for the microbiologic diagnosis of prosthetic-joint infection, but this method is neither sensitive nor specific. In prosthetic-joint infection, microorganisms are typically present in a biofilm on the surface of the prosthesis. We hypothesized that culturing of samples obtained from the prosthesis would improve the microbiologic diagnosis of prosthetic-joint infection. METHODS We performed a prospective trial comparing culture of samples obtained by sonication of explanted hip and knee prostheses to dislodge adherent bacteria from the prosthesis with conventional culture of periprosthetic tissue for the microbiologic diagnosis of prosthetic-joint infection among patients undergoing hip or knee revision or resection arthroplasty. RESULTS We studied 331 patients with total knee prostheses (207 patients) or hip prostheses (124 patients); 252 patients had aseptic failure, and 79 had prosthetic-joint infection. With the use of standardized nonmicrobiologic criteria to define prosthetic-joint infection, the sensitivities of periprosthetic-tissue and sonicate-fluid cultures were 60.8% and 78.5% (P<0.001), respectively, and the specificities were 99.2% and 98.8%, respectively. Fourteen cases of prosthetic-joint infection were detected by sonicate-fluid culture but not by prosthetic-tissue culture. In patients receiving antimicrobial therapy within 14 days before surgery, the sensitivities of periprosthetic tissue and sonicate-fluid culture were 45.0% and 75.0% (P<0.001), respectively. CONCLUSIONS In this study, culture of samples obtained by sonication of prostheses was more sensitive than conventional periprosthetic-tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection, especially in patients who had received antimicrobial therapy within 14 days before surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved diagnosis of periprosthetic joint infection by multiplex PCR of sonication fluid from removed implants.

The microbiological diagnosis of periprosthetic joint infection (PJI) is crucial for successful antimicrobial treatment. Cultures have limited sensitivity, especially in patients receiving antibiotics. We evaluated the value of multiplex PCR for detection of microbial DNA in sonication fluid from removed orthopedic prostheses. Cases of PJI in which the prosthesis (or part of it) was removed wer...

متن کامل

Sonication of antibiotic-loaded cement spacers in a two-stage revision protocol for infected joint arthroplasty

BACKGROUND Culturing of the sonication fluid of removed implants has proven to be more sensitive than conventional periprosthetic tissue culture for the microbiological diagnosis of prosthetic joint infection. Since bacteria surviving on antibiotic-loaded cement spacers used in a two-stage exchange protocol for infected arthroplasties may cause the persistence of infection, in this study we ask...

متن کامل

The use of 99mTc-recombinant human annexin V imaging for differential diagnosis of aseptic loosening and low-grade infection in hip and knee prostheses.

UNLABELLED The aim of this study was to assess the pattern of annexin V uptake in hip and knee prostheses suspected of being infected. METHODS A total of 7 patients undergoing revision surgery for hip or knee prostheses were studied; 5 patients had total hip replacements, and 2 had total knee replacements. Infection was confirmed by pathology, culture results, laboratory evaluation, and clini...

متن کامل

Sonication versus vortexing of implants for diagnosis of prosthetic joint infection.

Biofilm removal efficacy of vortexing alone was compared with the standard vortexing-sonication procedure. Among 135 removed prostheses, 35 were diagnosed with infection and 100 with aseptic failure. At a cutoff of ≥ 50 CFU/ml, sonication was more sensitive than vortexing (60% versus 40%, P = 0.151), while the specificity was 99% for both methods.

متن کامل

Periprosthetic Joint Infections

Implantation of joint prostheses is becoming increasingly common, especially for the hip and knee. Infection is considered to be the most devastating of prosthesis-related complications, leading to prolonged hospitalization, repeated surgical intervention, and even definitive loss of the implant. The main risk factors to periprosthetic joint infections (PJIs) are advanced age, malnutrition, obe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 357 7  شماره 

صفحات  -

تاریخ انتشار 2007