Changing hemodynamics in patients with transposition of the great arteries.
نویسندگان
چکیده
Follow-up cardiac catheterizations were carried out on 65 patients with transposition of the great arteries. Patent ductus arteriosus (PDA) was a significant problem in this group only when closure resulted in a precipitous drop in arterial oxygen saturation. Spontaneous closure of ventricular septal defects (VSD) occurred in approximately 20% of patients while natural or surgically created atrial septal defects (ASD) tended to persist. Pulmonary stenosis (PS) was found in 28% of patients with an intact ventricular septum and 50% of those with VSD. Pulmonary artery hypertension (PAH) or pulmonary vascular obstruction (PVO) or both, were present in about half of the patients with an intact ventricular septum and all the infants with a large VSD without pulmonary artery banding or pulmonic stenosis (PS). PS, usually but not invariably, tended to protect the pulmonary vasculature.
منابع مشابه
A 33-day-old Infant with the Transposition of the Great Arteries; A Rare Case Report
Dextro-transposition of the great arteries (d-TGA) is the one most common cyanotic congenital heart disease in neonates. The discordant ventriculoarterial arrangement results in parallel circulation, it so is vital to understand the management. We report a rare interesting but critical case of 33-day-old boy who developed cyanosis and had transposition of great arteries combined with interrupte...
متن کاملبررسی الگوهای شریان کرونری در جمعیتی از نوزادان مبتلا به جابجایی شریان های بزرگ
Background and purpose: Nowadays cardiovascular developments in pumping of heart-lung and improvements in anesthesia care, including intubation, have made early surgical intervention possible to correct life-threatening congenital anatomic abnormalities in patients of lower ages. This study was performed to evaluate the coronary artery patterns in neonates with transposition of the great arteri...
متن کاملSubpulmonary obstruction in congenitally corrected transposition of the great arteries due to ventricular membranous septal aneurysms.
The clinical, hemodynamic, and angiographic observations, as well as the surgical approach used for repair in three patients with congenitally corrected transposition of the great arteries and ventricular membranous septal aneurysms, are presented. In two of the three patients the membranous septal aneurysm caused subpulmonary obstruction, with 94 and 125 mm Hg systolic gradients. In each patie...
متن کاملAnatomic correction of transposition of the great arteries: pre- and postoperative cardiac catheterization, with angiocardiography in five patients.
Six of eight patients survived anatomic correction of transposition of the great arteries and repair of associated cardiovascular anomalies at the Hospital for Sick Children, Toronto, Canada. Two of the six survivors also had tricuspid atresia, and continuity between the right atrium and the subaortic outlet chamber in these patients was provided by a valved external conduit, in addition to the...
متن کاملTransposition of great arteries is associated with increased carotid artery stiffness.
Transposition of great arteries is the consequence of abnormal aorticopulmonary septation. Animal embryonic data indicate that septation and elastogenesis are related events, but human and clinical data are not available. We tested the hypothesis that large artery elastic function was impaired in patients with transposition of great arteries. We studied 34 patients aged 9 to 19 years, 12+/-3 ye...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 42 1 شماره
صفحات -
تاریخ انتشار 1970