Primary Atomic Frequency Standards at NIST

نویسندگان

  • D. B. Sullivan
  • J. C. Bergquist
  • J. J. Bollinger
  • R. E. Drullinger
  • W. M. Itano
  • S. R. Jefferts
  • W. D. Lee
  • D. Meekhof
  • T. E. Parker
  • F. L. Walls
  • D. J. Wineland
چکیده

The development of atomic frequency standards at NIST is discussed and three of the key frequency-standard technologies of the current era are described. For each of these technologies, the most recent NIST implementation of the particular type of standard is described in greater detail. The best relative standard uncertainty achieved to date for a NIST frequency standard is 1.5×10(-15). The uncertainties of the most recent NIST standards are displayed relative to the uncertainties of atomic frequency standards of several other countries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

918-t Annual Precise Time and Time Interval (PTTI) Meeting COMPARISON OF ATOMIC FREQUENCY STANDARDS AT NIST AND PTB USING CARRIER- PHASE GPS

We have constructed a link between Physikalisch-Techniche Bundesanstalt (PTB) in Braunschweig, Germany and the National Institute of Standards and Technology (NIST) in Boulder, Colorado using carrier-phase Global Positioning System (GPS) receivers. The link will provide a direct measurement of the frequency difference between UTC(PTB) and UTC(NIST), and can also be used to provide a direct comp...

متن کامل

Testing local position invariance with four cesium-fountain primary frequency standards and four NIST hydrogen masers.

We report the most sensitive tests to date of the assumption of local position invariance (LPI) underlying general relativity, based on a 7 yr comparison of cesium and hydrogen atomic clocks (frequency standards). The latest results place an upper limit that is over 20 times smaller than the previous most sensitive tests; this is consistent with the null shift predicted by LPI. The result is ba...

متن کامل

Second Generation Cesium Fountain Primary Frequency Standards at NIST

NIST is currently investigating the design of a second-generation cesium-fountain primary frequency standard. The design goals of this standard include an ultimate frequency inaccuracy of δf/f < 10 and achievable stability better than σy(τ) < 10/τ. This standard is expected to eventually replace NIST-F1, the current U.S. primary frequency standard [1]. In the context of reaching frequency uncer...

متن کامل

The optical calcium frequency standards of PTB and NIST ⋆ Les étalons de fréquence optique au calcium de la PTB et du NIST

We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) and the National Institute of Standards and Technology (NIST) make the frequency of the clock transitio...

متن کامل

Selecting a Primary Frequency Standard for a Calibration Laboratory

Calibration laboratories can choose from a variety of frequency standards, including quartz oscillators, atomic oscillators, and oscillators disciplined to agree with reference signals from the Global Positioning System (GPS) satellites or other sources. The frequency calibration and measurement capability of a laboratory is largely determined by the type of primary frequency standard* that is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 106  شماره 

صفحات  -

تاریخ انتشار 2001