Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel.
نویسندگان
چکیده
PURPOSE OF REVIEW This article reviews the development of novel reflectance pulse oximetry sensors for the esophagus and bowel, and presents some of the techniques used to analyze the waveforms acquired with such devices. RECENT FINDINGS There has been much research in recent years to expand the utility of pulse oximetry beyond the simple measurement of arterial oxygen saturation from the finger or earlobe. Experimental sensors based on reflectance pulse oximetry have been developed for use in internal sites such as the esophagus and bowel. Analysis of the photoplethysmographic waveforms produced by these sensors is beginning to shed light on some of the potentially useful information hidden in these signals. SUMMARY The use of novel reflectance pulse oximetry sensors has been successfully demonstrated. Such sensors, combined with the application of more advanced signal processing, will hopefully open new avenues of research leading to the development of new types of pulse oximetry-based monitoring techniques.
منابع مشابه
Photoplethysmography and Pulse Oximetry of Body Cavities and Organs*
Pulse oximetry is as a non-invasive photometric technique that provides non-invasively information about the global arterial blood oxygen saturation (SpO2 ) and heart rate, and has widespread clinical applications. This can be made possible via the peripheral pulse oximetry probes mainly attached to the finger, toe or earlobe. However, there is a need for monitoring perfusion on a more regional...
متن کاملInvestigation of Photoplethysmographic Signals in Human Visceral Organs
There is a need for reliable continuous monitoring of visceral organ oxygen saturation (SpO2). Splanchnic ischaemia may ultimately lead to cellular hypoxia and necrosis and may well contribute to the development of multiple organ failures and increased mortality. A new reflectance photoplethysmographic (PPG) probe and signal processing system were developed. PPG signals from abdominal organs (b...
متن کاملAutomatic detection of left ventricular ejection time from a finger photoplethysmographic pulse oximetry waveform: comparison with Doppler aortic measurement.
Left ventricular ejection time (LVET) is a useful measure of ventricular performance and preload. The present study explores a novel method of continuous LVET monitoring using a noninvasive finger photoplethysmographic pulse oximetry waveform (PPG-POW). A method for the automatic beat-to-beat detection of LVET from the finger PPG-POW is presented based on a combination of derivative analysis, w...
متن کاملPoor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients.
BACKGROUND To identify fluid responsiveness, a correlation between respiratory variations in pulse pressure (DeltaPP) and respiratory variations in pulse oximetry photoplethysmographic waveform amplitude (DeltaPOP) in mechanically ventilated patients has been demonstrated. To evaluate the agreement between the two methods, knowledge about the repeatability of the methods is imperative. However,...
متن کاملPhotoplethysmographic measurements from the esophagus using a new fiber-optic reflectance sensor.
A prototype fiber-optic reflectance-mode pulse oximetry sensor and measurement system is developed for the purposes of estimating arterial oxygen saturation in the esophagus. A dedicated probe containing miniature right-angled glass prisms coupled to light sources and a photodetector by means of optical fibers is designed and used to record photoplethysmographic (PPG) signals from the esophagea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Current opinion in anaesthesiology
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2008