Poly N-isopropylacrylamide and N-isopropylacrylamide/N-tert-butylacrylamide copolymer nanoparticles of 50-70 nm were prepared by free radical polymerisation. The particle sizes of the copolymer nanoparticles were measured in the test media Milli-Q water, Algae Media, Daphnia Media and Microtox Diluent as a function of temperature. Whereas in Milli-Q water the particle size was seen to decrease above the lower critical solution temperature of the thermoresponsive polymer, in the test media it was seen to increase significantly, indicative of aggregation. At the temperatures employed for the ecotoxicological studies all particles, with the exception of the 50:50 copolymer existed as nanoparticles. The zeta potential of Poly N-isopropylacrylamide and N-isopropylacrylamide/N-tert-butylacrylamide copolymer particles measured in the different media was seen to correlate well with the ratio of N-tert-butylacrylamide monomer and therefore the hydrophobicity of the particles. Ecotoxicological studies of the copolymer nanoparticles was performed using four test species Vibrio fischeri, Pseudokirchneriella subcapitata, Daphnia magna, Thamnocephalus platyurus and the cytotoxicity of the 100% Poly N-isopropylacrylamide and 85:15 N-isopropylacrylamide/N-tert-butylacrylamide copolymer nanoparticles was evaluated using a salmonid cell line. Although no significant cytotoxicological response was recorded, significant ecotoxicological response was observed at particle concentrations of up to 1000 mg l(-1). The ecotoxicological response was seen to correlate well with the ratio of N-tert-butylacrylamide monomer and therefore with the zeta potential of the nanoparticles. The toxic response in Daphnia magna was seen to further correlate with the reduction in zeta potential pointing towards a contribution of secondary effects due to modification of the medium. No correlation with particle size was observed. The sensitivity of the test species was seen to vary depending on copolymer composition. The relevance of the derived structure-activity relationships is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Characterization of Thermoresponsive Poly(N-isopropylacrylamide-co-acrylic acid)-Grafted Hollow Fe₃O₄/SiO₂ Microspheres with Surface Holes for BSA Release.

Thermoresponsive P(NIPAM-AA)/Fe₃O₄/SiO₂ microspheres with surface holes serving as carriers were prepared using p-Fe₃O₄/SiO₂ microspheres with a thermoresponsive copolymer. The p-Fe₃O₄/SiO₂ microspheres was obtained using a modified Pickering method and chemical etching. The surface pore size of p-Fe₃O₄/SiO₂ microspheres was in the range of 18.3 nm~37.2 nm and the cavity size was approximately ...

متن کامل

Preparation and Characterization of Thermoresponsive Poly(N-isopropylacrylamide-co-acrylic acid)-Grafted Hollow Fe3O4/SiO2 Microspheres with Surface Holes for BSA Release

Thermoresponsive P(NIPAM-AA)/Fe3O4/SiO2 microspheres with surface holes serving as carriers were prepared using p-Fe3O4/SiO2 microspheres with a thermoresponsive copolymer. The p-Fe3O4/SiO2 microspheres was obtained using a modified Pickering method and chemical etching. The surface pore size of p-Fe3O4/SiO2 microspheres was in the range of 18.3 nm~37.2 nm and the cavity size was approximately ...

متن کامل

Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

متن کامل

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

متن کامل

Small field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aquatic toxicology

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2009