The development and validation of an easy to use automatic QT-interval algorithm
نویسندگان
چکیده
BACKGROUND To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis. METHODS Additionally to standard ECG leads, the root mean square (ECGRMS), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECGRMS. T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers. RESULTS After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of <4ms and limits of agreement of ±25ms. Intra-class coefficient indicated excellent agreement (>0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers. CONCLUSION Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology.
منابع مشابه
Validation of a Novel Algorithm for Ventricular Repolarization Analysis: Use of Physionet Resources
Ventricular repolarization analysis allows extraction from the ECG signal of quantitative indexes (namely the QT interval), of prognostic value in unselected populations and cardiac patients, being related with arrhythmic risk. Several attempts to improve automatic ECG waveform detection have been accomplished, using signal derivatives, digital filtering, wavelet analysis, neural network techni...
متن کاملValidation of automatic measurement of QT interval variability
BACKGROUND Increased variability of beat-to-beat QT-interval durations on the electrocardiogram (ECG) has been associated with increased risk for fatal and non-fatal cardiac events. However, techniques for the measurement of QT variability (QTV) have not been validated since a gold standard is not available. In this study, we propose a validation method and illustrate its use for the validation...
متن کاملAutomatic Interpretation of UltraCam Imagery by Combination of Support Vector Machine and Knowledge-based Systems
With the development of digital sensors, an increasing number of high-resolution images are available. Interpretation of these images is not possible manually, which necessitates seeking for practical, fast and automatic solutions to solve the environmental and location-based management problems. The land cover classification using high-resolution imagery is a difficult process because of the c...
متن کاملA Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...
متن کاملDetermination of sensitivity and specificity of QT interval in ECG of diabetic patients for ndiagnosis of cardiac autonomic neuropathy
one of the important complications of diabetes mellitus that physicians pay less attention to is diabetic autonomic neuropathy(DNA) ,especially cardiac autonomic neuropathy (CAN).this has a poor prognosis and is accompanied by sudden death risk,recently several investigations that were carried out for CAN detection ,suggested that QT-interval prolongation in these patients is an important diagn...
متن کامل