Coagulation monitor based on serum migration through absorbent materials.
نویسنده
چکیده
I describe a method to measure blood coagulation properties, based on the hypothesis that the distance the serum component of a clotted plasma sample moves through a suitable absorbent material should be proportional to the blood's ability to clot. A simple apparatus was constructed to test this principle, in which an absorbent strip contacts clotted plasma samples. At various times, the liquid migration distance into the strip was measured and correlated with clotting times determined by well-accepted procedures. Use of this device to test lyophilized normal and barium-absorbed plasmas, factor VII-deficient plasma, frozen normal plasmas, plasmas from patients undergoing oral anticoagulation, and saline-diluted plasmas (as for Quick Percent assays) showed that clotting times correlated with migration distances for all types of samples (r2 = 0.93-0.99). The device distinguishes between samples from normal and coumadin-treated subjects. The concept can be integrated into an inexpensive, point-of-care coagulation monitor.
منابع مشابه
Nonsense-mediated mRNA decay among coagulation factor genes
Objective(s): Haemostasis prevents blood loss following vascular injury. It depends on the unique concert of events involving platelets and specific blood proteins, known as coagulation factors. The clotting system requires precise regulation and coordinated reactions to maintain the integrity of the vasculature. Clotting insufficiency mostly occurs due to genetically inherited coagulation fact...
متن کاملBlockade of Extracellular High-Mobility Group Box 1 Attenuates Systemic Inflammation and Coagulation Abnormalities in Rats with Acute Traumatic Coagulopathy
BACKGROUND As an extracellularly released mediator, high-mobility group box 1 (HMGB1) initiates sterile inflammation following severe trauma. Serum HMGB1 levels correlate well with acute traumatic coagulopathy (ATC) in trauma patients, which is independently associated with higher mortality. We investigated the involvement of HMGB1 in ATC through blocking extracellular HMGB1. MATERIAL AND METHO...
متن کاملMeasurement of VO2, VCO2, and evaporative water loss with a flow-through mask.
Equations for the calculation of VO2, VCO2, and evaporative water loss were derived for use of a paramagnetic gas analyzer with a flow-through respirometry system and an open or closed mask. The magnitude of errors involved in the determination of VO2 with no CO2 absorbent are small (+/-3%) but may be greater if no H2O absorbent is used, unless an appropriate correction is made for evaporative ...
متن کاملEffect of tear collection on lacrimal total protein content in dogs and cats: a comparison between Schirmer strips and ophthalmic sponges
BACKGROUND Quantification of lacrimal total protein content (TPC) is an important tool for clinical scientists to understand disease pathogenesis, identify potential biomarkers and assess response to therapy, among other applications. However, TPC is not only affected by disease state but also by the method used for tear collection. Thus, the purpose of this study is to determine the impact on ...
متن کاملA Novel Magnetic Graphene Oxide Composite Absorbent for Removing Trace Residues of Polybrominated Diphenyl Ethers in Water
The purpose of the study was to develop a facile method for the fabrication of a stable and reusable magnetic graphene composite absorbent to remove trace levels of polybrominated diphenyl ethers in water treatment. The poly cationic Fe₃O₄@PDDA (poly(diallyldimethyl ammonium chloride) (PDDA)) core-shell structured nanoparticles were first synthesized, and then, DNA was laid on the surface of gr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 43 9 شماره
صفحات -
تاریخ انتشار 1997